Install the pipe lining (customer-provided) in the
chimney. The connection height can be individual-
ly determined, however it should not exceed 1.5 m
mable material within a 20 cm radius around the
waste gas pipe, for the passage through structural
If desired, remount combustion air duct for the con-
combustion air duct for connection from below").
Fit the waste gas pipe (customer provided) on the
connection duct Ø 80 mm of the appliance.
Fit the combustion air line Ø 80 mm on the combus-
tion air duct.
Slide and align the stove at the intended installation
into the pipe lining.
The waste gas pipe connections must be sealed.
In order to clean the connecting line, bends with a
cleaning opening must be used.
The waste gas pipe must not project into the chim-
ney.
Bear in mind that on partition walls in accordance
of 85°C can be reached, and with light wallpaper
or similar combustible construction materials this
can result in colour changes.

for connection from below

Dismount the lower rear wall (Fig.2).
Unscrew the combustion air duct (Fig.3).
(Fig.4).
Remount the lower rear wall.
Seal the hole in the lower rear wall for the combus-
tion air connection at the back with the included cov-
er and screws.
-
lower rear wall
Fig.2
Fig.3
screws combustion air duct
Fig. 4
41