Electrical safety instructions
• When operating the product, the power plug must
be freely accessible after installation.
• Before you put your new pump into operation, have
it professionally checked:
- Earthing, connection of the neutral line and resid-
ual current circuit breaker must comply with the
safety regulations of the power supply compa-
nies and function properly,
- Protect the electrical plug connections from
moisture.
- If there is a risk of flooding, fit the plug connec-
tions in the flood-proof area.
• Ensure that the mains voltage corresponds to the
specifications on the type plate.
• Carry out the electrical installation in accordance
with the national regulations.
• Only connect the product to a socket with a residual
current circuit breaker (FI switch) with a rated resid-
ual triggering current of up to 30 mA; Fuse at least
6 amps.
• Before each use, always check the product, cable
and plug for damages. Defective cables must not be
repaired but replaced with a new ones.
Have product damages repaired by a specialist.
• If the connection cable of this product is damaged it
must be replaced by the manufacturer or their cus-
tomer services personnel or by a similarly qualified
person, in order to avoid hazards.
• Do not use the cable to pull the plug out of the out-
let.
• Protect the cable from heat, oil and sharp edges.
• Do not carry or attach the product by the cable.
• Use only extension cables that are splash-proof
and intended for outdoor use. Always unroll a ca-
ble drum completely before use. Check the cable for
damage.
• Pull out the mains plug before all work on the prod-
uct, in work breaks and when not in use.
• Mains connection cables shall not have a smaller
cross-section than rubber hose lines with the desig-
nation H05 RN-F. The cable length must be 10 m.
The conductor core cross-section of the extension
cable must be at least 1.5 mm
Lubricants are used inside the pump and can contami-
nate the drained fluids, if the product is improperly op-
erated or damaged.
.
2
www.scheppach.com
Warning! This power tool generates an electromag-
netic field during operation. This field can impair active
or passive medical implants under certain conditions.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.

6. Residual risks

The machine has been built according to the state-of-
the-art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Before maintaining or adjusting, switch off the prod-
uct and unplug the power plug.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the "Safety infor-
mation" and the "Proper use" together with the oper-
ating manual as a whole are observed.

7. Technical data

Dimensions L x W x H
Mains connection
Rated input
Max. delivery flow
Max. delivery height
Max. delivery pressure
Max. suction height
Pressure and suction
connection
Max. water temperature
Protection class
Protection category
Operating mode*
Weight
Technical changes reserved!
*Operating mode S1:Continuous operation at constant
load
452 x 175 x 309 mm
230V~ / 50 Hz
1000 W
4400 l/h
42 m
5 bar
8 m
G1"
35°C
I
IPX4
S1
7.9 kg
GB | 23