Symbols Used; Intended Use - Truma Combi 2 E Mode D'emploi

Masquer les pouces Voir aussi pour Combi 2 E:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Combi (E)
1
4
5
3
17
Figure 1
Table of Contents

Symbols used ...................................................................... 11

Intended use ........................................................................ 11

Safety instructions ........................................................... 12
Function description (Combi) .......................................... 14
Function description (Combi E) ....................................... 14
Control panels ................................................................... 15
Room temperature sensor .............................................. 15
Safety/drain valve ............................................................. 15
A. FrostControl ................................................................... 15
B. Safety/drain valve ........................................................... 15
Filling the boiler ................................................................ 16
Draining the boiler ........................................................... 16
Start-up .............................................................................. 16
Switching off .................................................................... 16
Maintenance ..................................................................... 16
Fuses .................................................................................. 17
Fuse 12 V ............................................................................. 17
230 V fuse (Combi E) ........................................................... 17
230 V overheating protection (Combi E) ............................. 17
Technical data ................................................................... 17
Dimensions .......................................................................... 17
Faults .................................................................................. 18
Troubleshooting guide (water supply) ................................. 18
Disposal ............................................................................. 18
Accessories ....................................................................... 18
Declaration of conformity ............................................... 19
Truma Manufacturer's Warranty ................................... 19
2
18
1 Control panel, digital or analogue (no picture)
2 Room temperature sensor
3 Cold water connection
4 Hot water connection
5 Gas connection
6 Warm air outlets
7 Circulated air intake
8 Exhaust gas discharge
9 Combustion air infeed
10 Electronic control unit
11 Water container (10 litres)
12 Burner
13 Heat exchanger
14 Power electronics
15 Heating elements 230 V
16 Overheating switch 230 V
17 FrostControl (safety/drain valve - UK version optional)
18 Safety/drain valve (UK version)
Symbols used
Symbol indicates possible hazards.
Note containing information and tips.
Intended use
The liquid gas heater Combi is a warm-air heater with in-
tegrated hot water boiler (10 litre volume). This unit was
designed for installation in motor homes and caravans. The
equipment must not be installed in buses or in vehicles for
transporting hazardous goods (vehicle classes M2 and M3).
11