Axis T99A11 Mode D'emploi page 24

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
AXIS T99A11 Positioning Unit 24 V AC/DC
1
I/O connector
2
Power connector
3
O-ring
NO
NO TICE
NO
TICE
TICE
Make sure the protective earth wire is about 10 mm (3/8 in) longer than the other two
wires (in the power cable), so that it will not be disconnected accidentally if pulled.
Note
We recommend that you strip approximately 90 mm (3½ in) of the power cable jacket and
70 mm (2¾ in) of the I/O cable jacket for ease of installation.
11. Install the power and I/O connectors, see Connectors on page 34.
12. Adjust the network, I/O and power cables so that the distance from the cable gasket to
the end of the connector is 240 mm (10 in), 170 mm (7 in), and 160 mm (7 in) respectively.
NO TICE
TICE
NO
NO
TICE
Make sure that the O-ring is fitted correctly around the transparent base unit cover.
24

Publicité

Table des Matières
loading

Table des Matières