Working instructions.
Before mounting or replacing application tools or accessories, remove the bat-
WARNING
tery. This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
For each job, use only the FEIN applica-
tion tool released and intended for the
respective application.
If power tool vibrations increase signifi-
cantly, check the setting parameters for
the respective application material and the
condition of the application tool.
Danger of injury from chip-
WARNING
pings. Always keep your
hands, clothing etc. away from chippings. Do
not attempt to remove the application tool
when still rotating. This can lead to serious
injuries.
Danger of injury from sharp
WARNING
edges of the milling head. Do
not touch the sharp edges of the milling head.
Switching on and off.
AKFH18-5T (**) (figure 12).
Switching on:
Slide the lock-off button toward the front.
Press the On/Off switch.
Switching off:
Release the On/Off switch.
Danger of burning. The appli-
WARNING
cation tool can become hot
during operation. Allow the application tool
to cool down:
– after placing the power tool down
– prior to tool changing.
When machining bevels and radii, pay atten-
tion that the correct speed stage is set depen-
dent of the material.
Various materials can be subject to hardening
at the edges due to heating, plasma or laser
cutting. This can lead to very high deviations
from the specified reference values.
Fig. 12
en
1.
2.
Lock-off button
On/Off switch
27