2 Technical Characteristics
2.1 General rules
Install the panel:
In vertical position +/-15°.
far from an hot source in dry places at maximum temperature of 45°C and
minimum 0°C.
In a ventilated place and easily accessible by an operator for periodical
maintenance.
At a suitable height above the chemical up to a maximum height of 1.5
meters. If for exigency of the plant it's necessary to install the pump under the
level of the chemical, you need to use an injection valve or an anti siphon
valve.
Do not install the pump over the tank in presence of liquids that emanate
fumes unless it is hermetically closed.
2.2 Standard Kit
1
A -TECHNOPOOL 3 pH/RX
2
Buffer Solutions
3
Suction and delivery tubes
4
pH and Rx Probe
5
Injection fitting x2
6
Foot filter x2
2.3 Hydraulic Connection
A-TECHNOPOOL 3 SYSTEM pH-RX