5.1.1 Manual activation of pumps and solenoid valve
The priming sub-menu can be accessed from the user menu, which allows the manual
operation of pumps and solenoid valve.
To access this menu, press key F for 3 seconds; the following options will be displayed:
A-TECHNOPOOL 3 SYSTEM pH-RX
pH corrector
Press keys ▼▲ to set manually the values to be dosed and
Enter to confirm and activate the dosing of the pH pump.
The dosing that can be set is 0÷999 ml or 1.0÷9.9 litres.
Rx corrector
Press keys ▼▲ to set manually the values to be dosed and
Enter to confirm and activate the dosing of the Rx/Cl/HP
pump.
The dosing that can be set is 0÷999 ml or 1.0÷9.9 litres.
Solenoid valve priming
Press keys ▼▲ to set manually the opening schedule of the
solenoid valve and Enter to confirm and activate its opening.
The schedule that can be set is 0÷50 seconds (at steps of 10
seconds) or 1÷60 minutes (at steps of 1 minute).
Temperature (is displayed only if the temperature is not
set on OFF)
Press keys ▼▲ to set the required temperature, only if the
temperature has been set manually.
The temperature can be set at 0÷100° C.
Press key F for 3 seconds to exit the priming menu, or exit
automatically after a minute without pressing any key.