Manual temperature or with PT100:
The two ON and OFF timings are proportional to the temperature reached during the latest
dosing, according to the diagram below:
To calculate exactly the dosing, the following formulas can be applied:
A-TECHNOPOOL 3 SYSTEM pH-RX
Relay On
It indicates the relay ON schedule (solenoid valve open).
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are 0÷59 seconds or 1÷60 minutes.
Relay On T. Max
Indicates the ON timing of the relay (solenoid valve open) to the
programmed maximum temperature value.
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set for the timing are 0÷59 seconds or 1÷60
minutes; whereas 23÷36° C for the temperature.
Relay Off
It indicates the relay OFF schedule (closed solenoid valve).
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are 0÷59 seconds or 1÷60 minutes.
Relay Off T. Max
Indicates the OFF timing of the relay (solenoid valve closed) to
the programmed maximum temperature value.
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set for the timing are 0÷59 seconds or 1÷60
minutes; whereas 23÷36° C for the temperature.
06/04/2016 Rev.1.5
17/100