6
Quick programming
6.1
Selection of the language of the system
Select option Language from the installer menu.
To confirm and exit, press key Enter for 3 seconds.
6.2
Setting the temperature
Select option Temperature from the installer menu.
To confirm and exit, press key Enter for 3 seconds.
A-TECHNOPOOL 3 SYSTEM pH-RX
Temperat. Mode
Indicates how the temperature is managed: manually,
automatically (with probe PT100) or OFF (deactivated).
Press keys ▼▲ to select the mode and Enter to confirm.
PT100 offset (only if the Temperat. Mode is PT100)
This parameter allows to adjust the temperature display. In fact,
the offset value can be added to or removed from the measured
temperature, so to display the desired value. This parameter is not
considered for the calculation of the dosing but only for the display.
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are -5.0÷10.0.
Man. Temperat. (only if the Temperat. Mode is Manual)
It represents the coefficient for calculating the compensation of
conductivity; it is recommended to leave the default value.
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are 0÷100° C.