A 12 A 19
5. 3. 4 ASSEMBLY
1 - Slide the drip tray into place.
2 - Fit bowl gasket to the bowl around its seat.
Place the bowl on the unit and then push it
down all the way. Fix the bowl by rotating
(2) it clockwise.
Wet the gasket for ease of insertion (see
figure 2).
3 - Push (1) the dispensing button and insert
(2) the pinch tube into its seat in the evapo-
rator bottom.
L i g h t l y p u l l ( 3 ) t h e p i n c h t u b e e n d
downwards till it is well arranged (see
figure 3).
4 - Use fresh product to chase any remaining
sanitizer from the bowl(s). Drain this
solution. Do not rinse out the machine.
5. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting
the machine may be performed, if needed,
only as further precaution, in addition to the
Disassembled Parts Sanitization described
before, but never in lieu of it.
1 - Prepare two gallons of a warm (45-60°C,
120-140 °F) sanitizing solution (100 PPM
available chlorine concentration or 1 spoon
of sodium hypoclorite diluted with two litres
of water) according to your local Health
Codes and manufacturer's specifications.
2 - Pour the solution into the bowl(s).
3 - Using a brush suitable for the purpose,
wipe the solution on all surfaces protruding
a bo v e t h e s ol ut i on -l ev e l an d o n t h e
underside of the top cover(s).
4 - Install the top cover(s) and operate the
unit. Allow the solution to agitate for about
two minutes. Drain the solution out of the
bowl(s).
5 - Use fresh product to chase any remaining
sanitizer from the bowl(s). Drain this
12
figure 3
solution. Do not rinse out the machine.
6 ROUTINE MAINTENANCE
Daily: inspect the machine for signs of product
leaks past seals and gaskets. If proper
assembly does not stop leaks around seals or
gaskets, check for improper lubrication, worn or
damaged parts. Replace parts as needed with
original spare parts from the supplier.
6. 1 MAINTENANCE (TO BE
CARRIED OUT BY QUALIFIED
SERVICE PERSONNEL ONLY)
Mo n tl y: clean all int ern al co mpon ent s,
primarily the condenser, using compressed air.
To clean these internal parts, unplug the unit or
switch off the 2-pole wall breaker, then remove
front panel (dispensing side).
Condenser fins are very sharp. Use extreme
caution when cleaning.
Ugolini S.p.A.