Bomba NIAGARA:Bomba NIAGARA.qxd 27/01/2010 18:01 Página 16
clean and in perfect condition for use"
In order to assemble the pump:
- Assemble the mechanical seal
(17/18), (page 42), assemble the rotary
part of the seal (17) above the back
flange of the impeller (16) by pressing
until this falls into the space; the
retainer will have been lubricated with
water beforehand.
- Assemble the impeller (16) on the
shaft (25) affixing it withLoctite or
similar int the threaded metal insert. In
this way, the two grooves of the
mechanical seal are joined (17/18).
- At the junction of the pump with the
motor, it must be borne in mind that the
diffuser flange (14), and all other
connections (13/19), must fit into the
correct space.
10. SPARE PARTS
To order any spare parts, indication
must be given of the denomination,
number shown on the detail drawing
(fig. 5 page 42) and nameplate ratings
(15 and 36).
16