en
Ventilation
The air on the rear panel of
the appliance heats up. Conduction of
the heated air must not be obstructed.
Otherwise, the refrigeration unit must
work harder. This increases power
consumption. Therefore: Never cover
or block the ventilation openings!
Cavity depth
A cavity depth of 560 mm
is recommended for the appliance.
If the cavity depth is smaller – at least
550 mm – the energy consumption
increases slightly.
Connecting
the appliance
After installing the appliance, wait at least
1 hour until the appliance is switched on.
During transportation the oil in
the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for
the first time, clean the interior of
the appliance (see chapter "Cleaning
the appliance").
Electrical connection
The socket must be near the appliance
and also freely accessible following
installation of the appliance.
The appliance complies with the
protection class I. Connect the appliance
to 220–240 V/50 Hz alternating current
via a correctly installed socket with
protective conductor. The socket must
be fused with a 10 to 16 A fuse.
24
For appliances operated in non-
European countries, check whether the
stated voltage and current type match
the values of your mains supply. This
information can be found on the rating
plate. Fig. +
Getting to know your
appliance
Please fold out the illustrated last page.
These operating instructions refer
to several models.
The features of the models may vary.
The diagrams may differ.
Fig. ç !
A
Refrigerator compartment
B
Freezer compartment
1
Temperature controller/light
2
Light switch
3
Glass shelf in the refrigerator
compartment
4
Vegetable container
5
Frozen food container
6
Door shelf
7
Shelf for large bottles