Télécharger Imprimer la page

Mendip Stoves Loxton 5 Manuel De L'utilisateur Et Mode D'emploi page 7

Publicité

Les langues disponibles

Les langues disponibles

Flue and Chimney connection to your stove (continued)
If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternately a draught
stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should in its closed position
leave a minimum continuous opening free area of at least 20 % of the total cross sectional area of the flue or flue pipe.
Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney and connecting flue
pipe
Your appliance needs to be maintained routinely, the throat plate/baffle should be cleaned regularly (monthly) . The flue
pipe can be cleaned using a flexible brush. Only Use a damp cloth on external surfaces. Over time the glass may become
dirty, clean with a damp cloth and polish off with damp cloth. If the stove has not been used for some time the flue should
be checked for blockages before use.
Do not modify the appliance; only use spares authorised by the manufacturer.
Loxton 5
606mm
Loxton 5 Maxi
750mm
Loxton 6
606mm
Loxton 8
660mm
Loxton 10
660mm
Churchill 5
606mm
Churchill 6
606mm
Churchill 8
660mm
Churchill 10
660mm
Sqabox unO
606mm
Sqabox duO
606mm
D
B
A
B
490mm
574mm
490mm
490mm
705mm
490mm
490mm
490mm
705mm
490mm
490mm
A
D
C
320mm
125mm
320mm
125mm
125mm
340mm
150mm
400mm
400mm
150mm
380mm
125mm
125mm
400mm
150mm
460mm
460mm
150mm
320mm
125mm
340mm
125mm
7
E
C
E
F
140mm
495mm
140mm
665mm
140mm
495mm
140mm
530mm
140mm
530mm
140mm
495mm
140mm
495mm
140mm
530mm
140mm
530mm
140mm
495mm
140mm
495mm
F
F
Logstore
N/A
N/A
847mm
905mm
905mm
N/A
847mm
905mm
905mm
N/A
N/A

Publicité

loading