Using your stove in a smoke control zone.
Only specific SE models are suitable for smoke control areas (see page 4), alterations should not be attempted.
Mendip smoke control stoves should not be burnt with the door left open.
The refuelling procedure : - allow the newly charged fuel to burn with the secondary air control set at maximum for up 3
to 4 minutes. After this period, with flames from the logs fully established, close the secondary air supply to the low
output setting. When operating at high output (secondary air set fully open) the new refuel charge does not require any
boost air to establish combustion.
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur.
Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in
a reasonable period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be operated
with air controls, appliance dampers or door left open except as directed in the instructions.
TO LIGHT YOUR STOVE (Solid Fuel)
Note: on cold days it maybe necessary to warm the flue using two firelighters.
1. Place Firelighters and a few smaller pieces of dry wood (kindling) among a small quantity of fuel in the combustion
chamber.
2. Fully slide open (pull out fully) the Universal air control (UAC) air slider below the stove door. Slide fully to the left
position. The stove now has total primary air for start up. (It maybe necessary to pull open ash pan 2 mm in some
conditions.)a bove stove door on right hand side. Light firelighters and securely close door.
3. With the fire established, open the door. And fill chamber with fuel, (see weight table on page 3) do not overload. (do
not cover tertiary air ports). Reloading is approximately every 2 hours.
4. Close fire door, set UAC control to mainly primary and 80% open.
5. Adjust as necessary.