MENDIP STOVES 5 YEAR EXTENDED WARRANTY If you have purchased your stove from a Mendip Stoves registered retailer, then your stove will carry a 2 year warranty as standard. The 2 year warranty can be further extended to a total warranty period of 5 years by registering your Mendip Stove within one month of the latter of the purchase date or installation date.
The use of any aerosol around lit stove is dangerous and care must be take in handling aerosols. IMPORTANT: hese instructions cover the basic principles to ensure the satisfactory installation of Mendip Stoves product :- Woodland models, although detail may need slight modification to suit particular local site conditions.
Page 5
Older properties, especially, may have chimney faults or the cross section may be too large . Mendip Stoves recommend the use of a solid fuel flue lining system for all installation into existing chimneys. All chimney systems must be used in accordance with Building Regulations Approved Document J.
Page 6
STOVE PERFORMANCE & TESTING Mendip Stoves, The Loxton & Churchill models are tested in accordance with EN 13240. Output Efficiency CO@13% Suitable for Output Coal Efficiency CO@13% O₂ Wood Fuel O₂ DEFRA Smoke Fuel Control Zones Churchill 8 7.5kW 79.3% 0.09...
Page 7
MINIMUM DISTANCE TO NON-COMBUSTIBLE MATERIALS The stove can be recessed in a suitable sized non - combustible fireplace but a permanent free air gap of at least 50mm must be left around the sides, the top and the back of the stove; this is to facilitate a reasonable heat output and allows access to the stove for removal and maintenance.
STOVE DIMENSIONS AND CONNECTION MEASUREMENTS DIMENSIONS DES POÊLES ET DE TAILLES DE RACCORDEMENT CHURCHILL 8 LOXTON 8 CHURCHILL 8 CONVECTION CHURCHILL 8 LOXTON 8 LOGSTORE / CONVECTION LOGSTORE / RANGE-BÛCHE RANGE-BÛCHE HEIGHT / Hauteur 665mm 665mm 1011mm 665mm 865mm 563mm 583mm WIDTH / Largeur 490mm...
Page 9
STOVE DIMENSIONS AND CONNECTION MEASUREMENTS DIMENSIONS DES POÊLES ET DE TAILLES DE RACCORDEMENT CHURCHILL CHURCHILL CHURCHILL 10 LOXTON 10 LOXTON 10 CONVECTION LOGSTORE LOGSTORE CONVECTION RANGE-BÛCHE RANGE-BÛCHE HEIGHT /Hauteur 665mm 665mm 1052mm 665mm 865mm 759mm 759mm 686mm 686mm 686mm WIDTH /Largeur 696mm 779mm 779mm...
Page 10
HOW TO FIT A LOXTON LOGSTORE Remove the internal components of the stove and fill the Tilt the stove onto it’s side to allow easy and safe access chamber with material to prevent the bricks from falling. to the feet. Unscrew the levelling bolts at the foot of the Additionally, prepare a soft elevated surface.
Page 11
Connection to chimney Mendip Stoves are built with a top flue outlet as standard, this can be altered to a rear connection by removing the top collar, rear cover plate then exchanging collar and plate. Care should be taken to ensure an airtight fit when refitting collar and plate.
Page 12
OPERATING YOUR STOVE - THE MK.4 AIR CONTROL LEVER The Universal air controller provides air control for the whole stove from a single lever. The Lever has two key operations Increased Air Supply Decreased Air Supply Moving the control lever in and out Sliding the control lever in reduces and out increases the total...
Page 13
HOW TO LIGHT YOUR WOODBURNING STOVE Note: If the chimney is externally fitted or the stove has been installed on a larger diameter clay chimney liner then on cold days it maybe necessary to warm the flue using firelighters prior to lighting with wood. .
DO NOT BURN HOUSE COAL. DO NOT BURN HOUSEHOLD WASTE. THIS APPLIANCE IS NOT AN INCINERATOR. MENDIP STOVES RECOMMEND THE USE OF A FLUE THERMOSTAT TO CHECK YOUR STOVE IS NOT OVERHEATING. PLACE FLUE THERMOSTAT DIRECTLY ABOVE COLLAR OF STOVE AND REFER TO TEMPERATURE GAUGE ON PAGE 5.
Page 15
RE-FUELLING WHEN BURNING WOOD Adding fuel to your stove when you only have glowing embers,and the flames have died down, is the cleanest way to refuel your stove. 1. Before refuelling, open the Universal Air Control (UAC) fully and slide to the central position. 2.
Page 16
ON THIS STOVE; ITS USE WILL INVALIDATE THE GUARANTEE. OVERNIGHT BURNING Mendip Stoves do not recommend burning registered smokeless coal in a slumbering position, Mendip stoves are designed to burn wood and quality registered smokeless fuels. Wood burns more efficiently and cleanly if it is burnt hotter. Mendip stoves do not recommend that their stoves are burnt overnight for this reason.
Page 17
MAINTENANCE Mendip stoves recommends that your model needs to have the ash removed from the stove at regular intervals (weekly if used daily). Allowing the ash pan to over flow can impede the function of the stove and can cause possible damage to the stove grate and ash pan.
Page 18
The SE appliances include a modified air control to prevent closure of the secondary air control, alterations should not be attempted. Mendip Stoves smoke control stoves should not be burnt with the door left open.:- Loxton 8 Churchill 8 & Woodland Large : This stoves needs no stop...
Page 19
CHURCHILL / LOXTON 8 / 10 MK.4 COMBUSTION CHAMBER CHURCHILL / LOXTON 8 / 10 MK.4 CHAMBRE DE COMBUSTION VERMICULITE BRICKS REFERENCE TABLE TABLE DE REFERENCE DES BRICKS DE VERMICULITE CODE DESCRIPTION PARTS / LES PIÈCES Churchill / Loxton 8 M90030-02-00-99-07 Full Brick Set - CHU/LOX 8 Mk.4 M90028-02-23-99-03...
HOW TO REMOVE THE WOODBURNERS INTERNAL PARTS MONTAGE ET DÉMONTAGE DE L’INTÉRIEUR To remove the vermiculite brick set take the following steps: Remove both of the vermiculite baffle bricks by lifting and tilting each brick in turn. To create more room to remove the first brick, lift up the adjacent baffle and rest a larger amount on the side brick. It is now possible to remove both side bricks;...
Page 21
CHURCHILL MK.4 DOOR ASSEMBLY / ECLATE DE PORTE LOXTON MK.4 DOOR ASSEMBLY / ECLATE DE PORTE 21 of 36...
STOVE PARTS, COMBUSTION CHAMBER, ASSEMBLY PIÈCES DÉTACHÉES, VUE ÉCLATÉES "This section shows the parts contained in your stove, each stove has over 80 spare-parts and, each part is detailed. When new parts are required the section will allow spares to be recognised and ordered. As a further source of reference please visit www.eurostove.co.uk for latest spare-part information.
Page 24
Ce manuel se réfère aux poêles énumérés ci-dessus. Ils ont été testés conformément à la norme EN 13240. Nous vous remercions d'avoir choisi un nouveau poêle de Mendip Stoves et nous sommes certains que vous en serez enchantés. Lisez ces instructions, elles relatent les principes de base pour assurer l'installation satisfaisante de votre poêle, même si pour répondre à...
à-dire, plus de 160 mm x 160 mm. La société Mendip Stoves conseille l'utilisation d'un système de conduit de fumée de combustibles solides pour l'installation dans des cheminées existantes. Tous les systèmes de cheminée doivent être utilisés conformément au Règlement de construction approuvé.
Les distances minimum des matériaux inflammables sont indiquées sur la plaque EN 13240 au dos du poêle à bois. DISTANCE MINIMUM AU MATÉRIEL Convenable plaque de COMBUSTIBLE MODELE POELE plancher CÔTÉS ARRIÈRE Churchill 8 Mk.4 100mm 600mm Churchill Convection 8 Mk.4 100mm 150mm Churchill 8 Range-bûche de Convection Mk.4 100mm 150mm Loxton 8 Mk.4...
FOYER Le foyer doit être capable de supporter le poids du poêle et de sa cheminée. Modèles , Churchill and Loxton 5, sont testés et adaptés pour être installés sur une plaque non combustible de 12 mm comme une plaque de sol verre de 12 mm ou une plaque d'ardoise de 20mm. L’Installation de tous les foyers doit se conformer à...
NE PAS BRÛLER DU CHARBON BRUN. NE PAS BRÛLER DES DÉCHETS DOMESTIQUES, CET APPAREIL N’EST PAS UN INCINERATÉUR MENDIP STOVES conseille l'utilisation d’un THERMOSTAT de cheminée pour vérifier que votre poêle ne surchauffe pas. Mettez le THERMOSTAT DIRECTEMENT AU-DESSUS DU POELE sur le conduit et comparer aux TEMPERATURES de références déclarées dans les tests (page 26).
Page 29
CONTROL D’AIR DU POÊLE A BOIS - Woodland , Le control Air universelle (UAC) permet un contrôle de l'air pour l'ensemble d'un poêle avec un seul levier de commande. Deux opérations importantes : Le déplacement du levier de commande avant et arrière Glisser le levier de commande vers l’arrière, vous réduisez la quantité...
COMMENT ALLUMEZ VOTRE POÊLE À BOIS MENDIP Remarque : Si la conduit est à l’extérieure et en période de grand froid, il peut être nécessaire de réchauffer la cheminée en utilisant les allume-feux préalable à l'allumage avec du bois 1. Placez des petits bouts de bois sec (petit bois) dans le foyer par-dessus les allume-feux non toxiques.
FONCTIONNEMENT PENDANT LA NUIT Mendip Stoves sont conçus pour brûler du bois et du Charbon sans fumée de qualité Comme un régime de temps de nuit, nous recommandons que la chamber de combusion est chargé quand il est chaud et brûlé...
ATTENTION Correctement installé, exploité et entretenu, votre poêle n’émettra pas de fumées dans l'habitation. Des Fumées occasionnelles lors du décendrage et du ravitaillement en bois peuvent se produire. Cependant, les émissions de fumées persistantes sont potentiellement dangereuses et ne peuvent pas être tolérées. Si les émissions de fumée persistent, suivez ces instructions: a) Ouvrez les portes et les fenêtres pour ventiler la pièce, puis quittez les lieux.
MAINTENANCE Mendip Stoves recommande de nettoyer régulièrement votre poêle, retirez la cendre (hebdomadaire si l’utilisation est quotidiennement). Utiliser un cendrier rempli par trop de cendre peut entraver le fonctionnement du poêle et peut causer des dommages sur la grille du poêle et sur le cendrier. Pour enlever le bac à cendre, utiliser l'outil et l’accrocher sur le devant du cendrier.
COMMENT INSTALLER LES PATTES D'UN RANGE-BÛCHES D'UN LOXTON Retirez les composants internes du poêle et remplissez la Inclinez le poêle sur son côté pour permettre un accès chambre avec un matériau empêchant les briques de facile et sûr aux pieds. Dévissez les boulons de mise à tomber.
Page 35
STOVE PARTS, COMBUSTION CHAMBER, ASSEMBLY PIÈCES DÉTACHÉES, VUE ÉCLATÉES "This section shows the parts contained in your stove, each stove has over 80 spare-parts and, each part is detailed. When new parts are required the section will allow spares to be recognised and ordered. As a further source of reference please visit www.eurostove.co.uk for latest spare-part information.
Page 36
Mendip Stoves Ltd. Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Website www.mendipstoves.co.uk Email info@eurostove.co.uk Telephone 01934 750 500 Part of the Eurostove Group Distribué en France par la société / Distributed in France and Benelux by: Eurostove SAS Centre d’Affaires...