11.3.4 Use of the continuous current

The continuous current AC socket is only applicable to charge the battery (12V).
During the operation process of the direct
current, turn the intelligent fuel-saving valve
to the "CLOSE" position.
First connected the charging cable (Fig. T) to
the direct current socket of the generator
Then link it to the junction side of the battery.
Start the engine
In order to prevent spark appearing around
the battery, first link the charging wire to the
generator, and then to the battery. The
dismantlement should start from the battery.
Before you link the charging wire to the
battery which is installed on the car, first
disconnect the battery's ground wire. Do not
connect the battery's ground wire until the
charging cable is dismantled. Such operation
will help to prevent short circuit or spark when you contact the junction side of the battery with
the car's frame or body uncarefully.
The battery will release explosive fuel, so it must
be kept away from spark, flame, or cigarettes.
Please charge it in the draught.
The battery contains acid (electrolytic cell). Once
your skin or your eyes have direct contact with
it, they will be burnt. Please wear exposure suit
and mask.
 If the electrolyte spatters on your skin, clean
it with water immediately.
 If the electrolyte spatters into your eyes, clean it with water immediately for at least 15
minutes, and go to the doctor at once.
 If you swallow it, drink a lot of water or milk at once. Then drink magnesia latex or vegetable
oil, and go to the doctor at once.
1 – Defender of the direct circuit (Fig. U)
2 – in ioperation -aktiv- (Fig. U)
3 – triggered -close- (Fig. U)

11.3.5 Low oil level alarming system

Low oil pressure alarming system is designed to
prevent the engine being damaged by lack of
machine oil in the crankcase. Before the machine oil
in the crankcase declines to the security line, the
low oil pressure alarming system will turn off the
engine automatically. (The switch of the engine will be still in the "OPEN" position.)
After low oil pressure alarming system has closed the engine, if you operate the starter again, the
low oil pressure alarming light will lighten (Fig. V), and the engine will not run. If this happens,
please add machine oil.
ZIPPER MASCHINEN GmbH
ZI-STE2000IV
www.Zipper-Maschinen.at
A T T E N T I O N
Do not try to start the car's
engine when the generator is
still connected with the
batteries, or else the generator
will be damaged.
The positive pole of the charging
cable should not be connected to the
negative pole of the battery. Do not
confuse the polarity of the charging
cable, otherwise serious results such
as damage of the generator and the
battery will be caused.
Keep the children away from it.
The electrolyte is toxic.
The direct current socket can
be applied when you are
using alternating current.
Overloading direct circuit may
make the defender of the direct
current trip. (The pressed switch
springs back.) If this happens,
wait for a few minutes, and then
press the defender again to re-
operate.