Settings For Each Type Of Battery; Settings - Cristec CPS2 Serie Manuel D'utilisation

Masquer les pouces Voir aussi pour CPS2 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.2.3 Settings for each type of battery

Type of battery
TYPE-1 BAT.
Calcium Lead Tin (e.g.:
Delphi/Delco Freedom)
TYPE-2 BAT.
Lead Sealed
TYPE-3 BAT.
Gelled Lead or Calcium Lead
TYPE-4 BAT.
Open Lead with maintenance
(free electrolyte)
WINTERING
for TYPE-1 BAT.
TYPE-2 BAT.
TYPE-3 BAT.
WINTERING
For TYPE-4 BAT.
(*)Voltage on BAT 1/BAT 2 with 10% of rated current and a tolerance of +/- 1%
Voltage on BAT D = BAT 1 or BAT 2 – approx. 0.4V

3.2.4 Settings

The shore-power unit's factory settings are:
TYPE-2 BAT. Sealed Lead (see table above)
BOOST in ON position
The installer should set the switches (excluding input and off-load output voltage) and possibly adjust the
output voltage using potentiometer RV1 (use the appropriate tool to turn the screw of the potentiometer),
depending on:
-
the type of battery (contact the battery manufacturer if necessary)
-
intended usage
-
the cross-section and length of the output cables
-
whether or not the boost function is required
For special batteries, call in a professional installer, who will make the specific settings in accordance with the
accumulator manufacturer's specifications and according to the specifics of the installation.
Cristec disclaims any liability in case of damage to batteries or ineffective recharging.
UECPS2-12-16/25/40-DEA.DOC
Switch positions
SW5
SW4
SW3
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
CPS2 12V
Voltage
Phase
SW1
SW2
*
Boost
Boost
ON
ON
15.1V
OFF
ON
14.3V
OFF
14.1V
ON
OFF
ON
13.7V
OFF
ON
14.1V
OFF
ON
13.7V
Voltage
Phase
*
Floating
14.4V
13.6V
13.4V
13V
13.4V
13V
24

Publicité

Table des Matières
loading

Table des Matières