5

COMMISSIONING

This paragraph lists all the tasks required to bring the equipment into service.
These instructions should be followed to the letter before first turning on the appliance.
5.1

ELECTRICITY NETWORK

All CPS2 shore-power units can operate automatically and equally on single-phase networks from 230VAC+/-
15% and from 47 to 63Hz.
Characteristics distribution AC :
General input protection by a 30mA / 16A differential circuit breaker.
AC outputs : protected by 2, 3 or 4 (depending on the model) thermo-magnetic circuit breaker DPN 10A.
Generators
The Cristec shore-power unit is designed to operate on a generator. In certain cases, generators can produce
high surges. Before connecting the shore-power unit, check its compatibility with the generator's
characteristics: power, voltage, surges, frequency, current etc.
5.2
SHORE-POWER UNIT COMPATIBILITY AND SETTINGS ACCORDING TO BATTERY
TYPE
Before switching on, be sure to check the compatibility of voltage, current and settings according to the type of
batteries connected.
Checking the load voltage
Before connecting the batteries to the shore-power unit, you must check the polarity of the accumulators. Also
check the voltage of the batteries with the aid of a calibrated voltmeter. A low voltage on certain types of
accumulators may indicate they have sustained irreversible damage, thereby precluding any possibility of
recharging.
5.3

TURNING THE SHORE-POWER UNIT ON AND OFF

The CPS2 shore-power unit starts operating as soon as it is switched on (input power cable connected and
powered).
The CPS2 shore-power unit stops operating when it is no longer powered up (input power cable disconnected
or the installation's circuit-breaker in the OFF position).
ATTENTION: if the charger On/Off option is used, the charger may not be in operation while the shore-power
unit is still being powered up (dangerous voltage).