2 TECHNICAL SPECIFICATIONS
2.1 UECPS2 12V/16A, 12V/25A, 12V/40A
Model
Input
Voltage
Frequency
Current intensity 230VAC
Power factor
Efficiency
Input fuses F1/F2
Output
Number of outputs
Overall rated current (+/-7%) / Rated
power
Load curve
Type of batteries
Regulated and filtered output voltage
Regulation tolerance before distributor
and fuses
Peak-to-peak ripple and noise
Automotive output fuses mounted in
parallel in the BAT pole -
Environment
Operating temperature
Cooling
Relative humidity
Storage temperature
Case
Material
Paintwork
Dimensions excluding cable gland (length,
height, depth)/Weight
Fixing centre distances
Wall screw
Protection factor
Board protection
Standards
CE/CEM markings
CE/safety markings
Electrical protection
UECPS2-12-16/25/40-DEA.DOC
UECPS2/12-16
UECPS2/12-25
230VAC +/-15%, single-phase
From 47 to 63Hz
1,4A
0.9 in rated conditions
> 80% in rated conditions
2 x 6.3A/250V – Ref. DEL MICRO
FUSE 00346623MST
3 separate outputs BAT D, BAT 1 and BAT 2 (integrated distributor). Each
output can be used on its own and supply the entire current.
16A/228W
Type of charge selected using internal switch IU or IUoU (Boost, Absorption,
Floating – factory setting).
See switch settings table
See switch settings table. Chargers can operate on DC supply.
< 2%
< 250mV
1 x 20A/32V (F3) 1 x 25A/32V (F3)
-10°C to +45°C ; +45°C to +50°C with 10% de-rating of rated Power/°C
Natural
Draft fan controlled by internal temperature probe 60°C
dissipation
Up to 70% (95% with no condensation)
-20°C to +70°C
Case comprises 2 parts: aluminium frame and steel front cover
Mat black and grey epoxy coating
375 x 242 x
375 x 242 x
106mm / 3,6Kg
106mm / 3,7Kg
357x 190mm
357x 190mm
4 M5 round screws
IP21
Protected with water-repellent varnish (marine environment)
NF EN6100-6-1, NF EN6100-6-2, NF EN6100-6-3, NF 6100-6-4
NF EN60950, NF EN603635-2-29
-Against leaking input surges by rupture of VDR (voltage-dependent resistor)
-Against output polarity reversals by rupture of fuses
-Against output short-circuits and surges
-Against abnormal overheating by cutting off the charger (internal
temperature probe 90°C)
-Against output surges
UECPS2/12-40
2A
3,2A
2 x 10A/250V –
6,3x 32
25A/356W
40A/570W
< 250mV
< 250mV
2 x 20A/32V
(F3/F4)
+/-5°C
395 x 262 x
116mm / 5,6Kg
377 x 190mm
22