CHARGING PROGRAMS AND OPTIONS COMBINATIONS
DESULPHATION
15.8V
15.8V
+
15.8V
+
RECOND
15.8V
+
+
RECOND
15.8V
15.8V
+
15.8V
+
RECOND
15.8V
+
+
RECOND
Limit:
14 • EN
20018888_C.indd 12
SOFT START
BULK
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
4.3A until 12.6V
Increasing voltage to
14.4V. 4.3A
4.3A until 12.6V
Increasing voltage to
14.7V. 4.3A
4.3A until 12.6V
Increasing voltage to
14.4V. 4.3A
4.3A until 12.6V
Increasing voltage to
14.7V. 4.3A
Max 8h
Max 20h
ABSORPTION
ANALYSE
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Max 10h
3 minutes
RECOND
FLOAT
13.6V
0.8A
13.6V
0.8A
Max 15.8V
13.6V
0.3A
0.8A
Max 15.8V
13.6V
0.3A
0.8A
13.6V
4.3A
13.6V
4.3A
Max 15.8V
13.6V
1.5A
4.3A
Max 15.8V
13.6V
1.5A
4.3A
10 days
30 min or 4h
Charge cycle
depending on
restarts if
battery voltage
voltage drops
PULSE
12.7V–14.4V
0.8–0.4A
12.7V–14.7V
0.8–0.4A
12.7V–14.4V
0.8–0.4A
12.7V–14.7V
0.8–0.4A
12.7V–14.4V
4.3A–2A
12.7V–14.7V
4.3A–2A
12.7V–14.4V
4.3A–2A
12.7V–14.7V
4.3A–2A
Charge cycle
restarts if
voltage drops
2017-05-24 13:20:45