Very Important Notes
1. The F-3 Fazer features a self-cleaning liquid pipe function. After operation, keep the
machine connected to the mains until all liquid is drained from the liquid pipe. The
cleaning takes about 3 minutes.
2.
Please clean the ventilation filter at the bottom of the machine regularly. Always
make sure there are no foreign objects nor dust at the bottom that could prevent
proper ventilation.
Technical Specifications
Model
Power supply
Heater
Output volume
Fluid consumption
Warm-up time
Tank capacity
Weight
Dimensions (LxWxH)
DMX
Control
F-3
AC 100~120 V, 50/60 Hz or AC 220~240 V,
50/60 Hz
800 W
3,000 cu.ft/ min (approx. 85 m³/min.)
5 hrs./liter
90 seconds
2.7 liters
20.5 kg
540 x 500 x 235 mm
On-board
Blue LCD screen, Timer mode, Volume mode
Please read and save these instructions.