4.6 Max. time to wait until „0" is displayed
This parameter indicates, how long it takes at
active measuring, until „0" is displayed
4.7 End of programming
max. time to wait 01.1 s
(min. value)
max. time to wait 99.9 s
Programming routine will
be passed through once
again. All parameters can
be checked.
Programming routine will
be left and the new
parameters will be stored.
Afterwards the device is
ready to use.
5. Terminal assignment
5.1 Terminal assignment X2
Terminal no.
AC version
1
Supply voltage
90..260 VAC
2
Supply voltage
90..260 VAC
5.2 Terminal assignment X1
Terminal no.
AC version
1
Optocoupler output Emitter
2
Optocoupler output Collector
3
n.c.
4
n.c.
5
INP
6
GND out
7
+24 V out
6. Delivery includes:
- Codix 542
- Panel mounting clip
- Sealing
7. Ordering code:
6.542.01X.X00
Voltage supply
0 = 90..260 VAC
3 = 10..30 VDC
Output
1 = Opto coupler
2 = no output
X1
X2
10..30 VDC
version
0 VDC
GND
Supply
voltage
10..30 VDC
10..30 VDC
version
nc.
nc.