Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or
accessories and repair and servicing of equipment shall be performed
only by a qualified agency. The term "qualified agency" means any
individual, firm, corporation or company which either in person or through
a representative is engaged in and is responsible for (a) the installation
or replacement of gas piping or (b) the connection, installation, repair or
servicing of equipment, who is experienced in such work, familiar with
all precautions required and has complied with all the requirements of the
authority having jurisdiction.
The installation must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54* Natural
and Propane Installation Code, CSA B149.1.
*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York,
N.Y. 10036.
Clearances
1. In selecting a location for installation, it is necessary to provide adequate
accessibility clearances for servicing and proper installation.
2. The FAW-40 can be attached to the wall or recessed into the wall up
to 9 1/2 inches (24.1cm) in depth. Note: Do not place combustible
header or material on top of unit when installed in wall. Maintain
3/4" minimum spacing above heater.
3. The wall in which the furnace is recessed has (0) zero (0mm) clearance
to the furnace sides.
4. When using side discharge registers, SOR-1 or SOK-1, the furnace
cannot be recessed into the wall.
5. Clearance to sidewall or combustible material is 4 inches (10.2cm).
6. Ceiling clearance is 4 inches (10.2cm).
7. Floor and rear wall clearance is (0) zero inches (0mm).
8. Clearance of 18 inches (46cm) is required to adjacent wall or combustible
material when flush mounted SOR-1, side outlet register is used.
Before Installing Consider The Following Venting
1. A chimney for residential-type or low-heat gas utilization equipment
shall extend at least 3 feet (914mm) above the highest point where it
passes through a roof of a building and at least 2 feet (610mm) higher
than any portion of building within a horizontal distance of 10 feet
(3m).
2. This furnace must not be connected to a chimney flue serving a separate
solid-fuel burning appliance.
3. Uninsulated Single-Wall Metal Pipe shall not be used outdoors in
cold climates for venting gas utilization equipment.
4. Attention! This Fan Type Vented Wall Furnace is equipped with a vent
safety switch. In the event of spillage of flue products due to improper
venting the vent safety switch will open, which results in the main
burners to "shut off".
Model No. FAW-40 may be vented as shown in Figure 4. The vent cap
termination must be at least 12 feet (3.7m) above the floor and must exhaust
to the outdoors.. Clearance to combustible construction is held by the fixed
spacers at 1 inch (25mm) with B-1 or (B-W) vent pipe. Installation must
conform to local codes.
A. 4" (102mm) Round (all parts purchase locally except Item 2)
1. Type B-1 round pipe
2. Part No. DV-648, 4" (102mm) oval-to-round flue adapter kit (see
accessories)
3. Single story type B-1 gas vents require a baseplate and one pair
of ceiling plate spacers.
4. Multi-story type B-1 gas vents require a baseplate, one pair of
ceiling plate spacers at the first floor ceiling and one pair of fire
stop spacers at each successive ceiling level.
B. 4" (102mm) Oval (all parts purchase locally)
1. Type B-1 oval pipe or B-W vent pipe
2. Single story type B-1 or (B-W) gas vents require a baseplate and
one pair of ceiling plate spacers.
3. Multi-story type B-1 or (B-W) gas vents require a baseplate, one
pair of ceiling plate spacers at the first floor ceiling and one pair
of fire stop spacers at each successive ceiling level.
C. 4" (102mm) Oval In-The-Wall (all parts purchase locally)
12427-7-1007
1. Type B-1 oval pipe or B-W vent pipe
2. Type B-1 oval elbows or B-W oval elbows
3. Single story type B-1 or (B-W) gas vents require a baseplate and
one pair of ceiling plate spacers.
4. Multi-story type B-1 or (B-W) gas vents require a baseplate, one
pair of ceiling plate spacers at the first floor ceiling and one pair
of fire stop spacers at each successive ceiling level.
Stud space around gas vents must be free of obstructions and building
paper.
4" ROUND
ADAPTER
WALL
BASEPLATE
A.
SIDE
4" B-1 OVAL
BASEPLATE
B.
4" B-1 OVAL
4" 45 DEG.
OVAL ELBOWS
C.
4" B-1 OVAL
SPACER
BASEPLATE
C.
VENT
ENCLOSURE
FRONT
BRACKET
SPACER
BASEPLATE
Figure 4
Page 5