LiftMaster LJ8900W Mode D'emploi page 28

Masquer les pouces Voir aussi pour LJ8900W:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting
Additional Troubleshooting (Continued)
The door operator won't operate due to power failure:
Disable any door locks. Use the emergency release handle to disconnect the door. The door can be opened and closed manually.
When power is restored, pull manual release a second time.
When in battery backup mode, battery power will last for 30 hours or up to 20 cycles over a 24 hour period.
Door loses limits:
Collar not tightened securely. Tighten collar and reprogram limits (see Adjustment Step 1).
The door operator moves when the door is in operation:
Some minor movement is normal for this product. If it is excessive the collar will wear prematurely.
Check to make sure the torsion bar is not moving left/right excessively.
Check to make sure the torsion bar is not visibly moving up and down as it rotates.
Check that the door operator is mounted at a right angle to the Jackshaft. If not, move the position of the mounting bracket.
Automatic door lock connector will not fi t the door operator plug:
Older model 24V door locks are incompatible. Use automatic door lock model 841LM, see Accessories page 30.
The door operator is beeping:
Indicates unattended closure. The operator has been activated by the MyQ App or the Garage and Gate Monitor.
A solid orange LED with beep, sounding approximately every 2 seconds, indicates the door operator is operating on battery power.
A fl ashing orange LED with beep, sounding every 30 seconds, indicates the battery is low.
A solid red LED with beep, sounding every 30 seconds, indicates the 12V battery will no longer hold a charge and needs to be
replaced.
28

Publicité

Chapitres

Table des Matières
loading

Table des Matières