RESETTING THE APPLIANCE
If the safety thermostat is
tripped, the appliance has to
be restored to the initial work-
ing conditions as follows.
1 - Pull off the knobs (A).
2 - Undo the screws to re-
move
the
control
panel (B).
3 - Press the button (C) of
the safety thermostat to
restore the electricity
supply.
4 - Replace the control pan-
el (B) and the knobs (A) on completion of the
operation.
TESTING OF THE APPLIANCE
Important
Before it is put into service, the system must
be tested to check the operating conditions
of every single component and identify any
malfunctions. In this stage, it is important to
check that all health and safety requirements
have been complied with in full.
To test the system, make the following checks:
1 - check that the mains voltage is the same as that
The appliance's main functions do not require any
special adjustments by specialist staff except the
The appliance does not require the replacement of
operating components by specialist staff except the
DECOMMISSIONING THE APPLIANCE
Important
This operation must be carried out by skilled
operatives in compliance with the legal re-
quirements with regard to safety at work.
Never dump non-biodegradable materials,
lubricating oils and non-metallic compo-
A
ADJUSTMENTS
REPLACING PARTS
- 15 -
B
of the appliance;
2 - operate the appliance's circuit-breaker to
check the electrical connection;
3 - check that the safety device is operating
correctly.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.
settings made during use by the user.
replacement of standard parts which can be carried
out by the user.
nents (rubber, PVC, resins, etc.) in the envi-
ronment. Dispose of them in accordance
with the relevant legal requirements.