SOMFY RS485 4 ILT Interface Notice D'installation Et D'utilisation page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
WIRING
Motor wiring
1) 4xILT plugs (plug directly the ILT motor
to the RJ9 plug).
Controls wiring
1) Trigger (For videoprojector)
+ : 5 → 30V
G : Ground
2) IR (Use a Somfy IR sensor)
3) RS485:
+V: Not connected
B: RS 485 B
A: RS 485 A
G: Ground
Power wiring
Connect the interface to a standard AC
power source
COMMISSIONING
Commissioning must be performed with a Somfy 8 channels IR remote control
prior to any use.
ILT motors will not react to any control as long as they are not set.
To set ILT motors, please refer to MOTOR SETTING.
ILT motors may have been already set prior to this installation by the means of a
dedicated setting tool by the manufacturer.
If more than one motor only is connected to the interface, you need to set each
motor separately before setting the differents formats.
By default, all motors connected to the interface will react together to any opera-
tion.
To select a motor, please refer to : MOTOR SELECTION
Copyright © 2008 Somfy SAS. All rights reserved - V0 - 09/2008
1
3
1
2
3

Publicité

Table des Matières
loading

Table des Matières