Connecting an antenna for the 433 MHz RF module (see "R2" fig. 1)
The receiver is supplied with its own antenna which consists of a piece of rigid wire 170 mm in
length. In alternative it is possible to connect an ANS400 tuned antenna using a coaxial cable RG58
(impedance 50Ω) with a maximum length of 15 m.

FUNCTION MODE

Functions selected using the Dip-switch "S2"
Pos. A (Dip 1 "ON" + Dip 2 "ON")
Automatic reclosing + limited dynamic button mode using the
sequence "Open- Close" (with travel direction inversion only
during the closing stage)
Pos. B (Dip 1 "OFF" + Dip 2 "OFF")
Automatic reclosing excluded + normal dynamic button mode
using the sequence "Open-Block-Close-Block"
Pos. C (Dip 1 "ON" + Dip 2 "OFF")
Automatic reclosing excluded + limited dynamic button mode
using the sequence "Open- Close" (with travel direction
inversion only during the closing stage)
Pos. D (Dip 1 "OFF" + Dip 2 "ON")
Automatic reclosing + normal dynamic button mode using
the sequence "Open-Block-Close-Block"
Functions selected using the jumper "J1"
Pos. A (jumper open)
Manual operating mode disabled
Pos. B (jumper closed)
Manual operating mode enabled
1) Automatic
Selected by moving dip 2 to the "ON" position.
When the door is completely closed the opening command will start a complete cycle consisting of
opening and automatic reclosing. Thirty seconds after the door is completely closed the timer will
switch off the night lights.
Automatic reclosing starts after the programmed pause period has elapsed when the opening cycle
has been completed or straight away after the intervention of a photoelectric cell (the intervention of
a photoelectric cell causes the pause time to be reset).
The indicator light remains lit until the closing manoeuvre has terminated
Note: the night light switches on automatically each time a movement command is given either by
control button or by radio. The intervention of a photoelectric cell during reclosing has no effect on
the timing of the night light.
2) Semi-automatic
Selected by moving dip 2 to the "OFF" position.
Work cycle control using separate opening and closing commands.
When the door has reached the completely open position the system will wait, until it receives a
closing command either via an external control button or via radio control, before completing the
cycle. Starting from the opening manoeuvre the night light will switch off after the following period
has elapsed: pause time + closing time + 30 seconds.
The indicator light remains lit until the closing manoeuvre has terminated.