ELECTRICAL CONNECTION

• Before connecting the appliance make sure that the voltage and frequency rated on the data plate
conform to those of the mains supply.
Note: the installer must set the torque selector switch to the appropriate voltage depending on the
weight and dimensions of the gate/door which is to be automated. The safety standards indicate a
maximum thrust at the head of the gate equal to 15 kg.
• Connect the control wires, the security devices, the motor cables and other 230Vac devices.
• Connect the power supply cable to the device
Terminal board connections
TA (contact N.O.) Opening button in input
1
TC (contact N.O.) Closing button in input
2
TD (contact N.O.) Dynamic button in input "Open-Close"
3
4
TB (contact N.C.) Blocking button in input (The opening of this contact will interrupt the cycle
until a new movement command is given).
5
FTCI (contact N.C.) Safety and control devices in input (photocells invert the travel direction
when an obstruction is detected) The opening of this contact will provoke a travel direction
inversion during closure due to the cutting in of the safety device.
FCC Motor 1-2 closing travel limit in input (contact N.C.)
6
FCA Motor 1-2 opening travel limit in input (contact N.C.)
7
8...12
Common for all inputs and outputs (negative)
Electronic locking device 12Vac 15W max. output (only in opening)
13
14
24Vac 10W in output, powering external devices (Photoelectric cells, etc.)
15
LS 24Vac 3W in output. Indicates an opening/closing cycle in course. It turns off at the end
of the cycle.
16
LP 24Vac 10W flashing warning lamps indicating gate in movement
17-18
Second channel exchange contact in output (only when a 2-channel receiver card or an RF
module is used).
230Vac 40W night light in output
19-20
21-22-23 Motor M1 in output Opening- Closing- Common
24-25-26 Motor M2 in output Common- Opening- Closing
Electronic programmer power supply 230Vac 50/60Hz
27-28
29
Earth binding post (mains supply)
30
Motor earthing wire (in output)
31
Radio receiver antenna 2 (N.B. The antenna must be connected using a coaxial cable with
an impedance of 50Ω)
32
Mass for radio receiver antenna 2
33
Radio receiver antenna 1 (N.B. The antenna must be connected using a coaxial cable with
an impedance of 50Ω)
34
Mass for radio receiver antenna 1
NOTE: ALL UNUSED NC CONTACTS MUST BE JUMPED
Setting the torque limiter
The torque can be set to minimum, seeing as the appliance will give a maximum power thrust each
time it receives a movement command
equals: 120Vac
Position
"MIN"
equals: 145Vac
Position
"A"
equals: 170Vac
Position
"B"
Position
"C"
equals: 195Vac
Position "MAX"
equals: 230Vac