RIB J Mode D'emploi page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A - CONNECTIONS
J1
L-N
230VAC 50/60HZ POWER SUPPLY (120VAC/60HZ UPON
REQUEST)
J2
COURTESY LIGHT OR BLINKER (MAX 40W )
U
MOTOR COMMON CONNECTION
V-W
MOTOR PHASES AND CAPACITOR CONNECTIONS
J3
AERIAL
RADIO ANTENNA
A+A-
POWER SUPPLY FOR ACCESSORIES 24VDC
COM.
CONTACTS COMMON UNIT
K BUTT.
CONTACT OF A SINGLE IMPULSE (NO)
PHOTO
PHOTOCELLS CONTACT (NC)
EDGE
SAFETY STRIP CONTACT IN OPENING AND CLOSING (NC)
A+ TEST
ACCESSORIES POWER SUPPLY +24VDC
FUSES
F1 =>
T100mA
F2 =>
T5A
RELAYS AND MOTOR CONTROL
K1 =>
Flasher control
K2 =>
Opening travel control
K3 =>
Closing travel control
Q4 =>
TRIAC Motor control, open and close
B - SETTINGS
OPERATION MICROSWITCHES
DIP 1 ON -
CHECKING THE ROTATION DIRECTION OF THE MOTOR (POINT C)
DIP 1 ON -
ENABLING OF MANNED POSITION SETTING (POINT D)
DIP 2 ON -
TIMING (POINT E)
DIP 1-2 DIP1 ON FOLLOWED BY DIP2 ON
READ IN/CANCELLATION RADIO CODES FOR MOTOR CONTROL ONLY
FOR CRX MODELS (POINT F)
OPERATING MICROSWITCH
DIP 3
ON
- Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON
- Photocells active only in closing
OFF - Photocells always active
DIP 5
ON
- For external flasher
OFF - For internal courtesy light
DIP 6
ON
- STEP BY STEP
Single pulse contact (K BUTT)
OFF - AUTOMATIC
Single pulse contact (K BUTT)
DIP 7
ON
- Safety strip self test ENABLED
OFF - Safety strip self test DISABLED
DIP 8
ON
- Blinker pre-flashing
OFF - Blinker normal flashing
TORQUE - ELECTRONIC TORQUE REGULATOR
The torque is regulated by rotating the Trimmer TORQUE, varying the output voltage of motor
ends,(when rotated clockwise, more torque Is transmitted to the motor).
Such torque is automatically included 3 seconds after the start of every
operating cycle.
This allows the motor to have the maximum pickup when it starts.
NOTE: IN CASE THE ABOVE TRIMMER IS SET FOLLOWING THE PROGRAMMING PROCEDURE,
THE SLOWING STROKE STARTING POINT CAN CHANGE (ANTICIPATING OR DELAYING
THE SET VALUE), THEREFORE UPON A NEW TRIMMER SETTING, A NEW TIME
ADJUSTMENT IS RECOMMENDED.
J4
SW J AND RADIO
DO NOT TOUCH THE JUMPER ! IF IT IS
REMOVED THE OPERATOR DOESN'T MOVE !
CRX
NOT CRX
J5
RADIO
CONNECTOR FOR EXTERNAL RADIO RECEIVER 24VDC
(NOT CRX MODELS)
J6
RADIO
IN BUILT RADIO MODULE (MODELS CRX)
TR1
TORQUE
ELECTRONIC TORQUE REGULATOR
S1
PROG.
PUSH-BUTTON FOR THE PROGRAMMING
,
LED SIGNALS
DL1 - (Red)
- Programming operated
DL2 - (Green)
- Radio programming activated (models CRX only)
DL3 - (Red)
- Safety strip contact (NC)
DL4 - (Red)
- Photocell contact (NC)
DL5 - (Red)
- K BUTT command light
DL6 - (Red)
- Shutter is closing
DL7 - (Green)
- Shutter is opening
C - CHECKING THE ROTATION DIRECTION OF THE MOTOR
This control is carried out to facilitate the installation of the system or any possible future
control.
WITH FENCE LOWERED AND LOWER STROKE END SWITCH CORRECTLY SET.
1 - Put DIP1 in the ON mode => The LED DL1 starts blinking;
CAUTION:
in case the pushbutton PROG is not operated within 1 min, the LED
turns off, the system maintains the present configuration, see para.
"D-MANNED POSITION SETTING".
2 - Depress and maintain the pushbutton PROG (motion is performed in manned position
setting, open-stop-close-stop-open-etc.) the fence will open (DL7 green lit).
a - In case the fence closes instead of opening (DL6 RED LIT) release immediately the
pushbutton PROG and set the close stroke end switch.
b - In case the fence closes instead of opening (DL7 GREEN LIT) exchange the
connection of motor wires V and W on the electrical unit, or connection blocks 5
and 6 on the stroke end unit JOLLY.
3 - Set the opening stroke end switch. Ensure the end stroke system stops the motor on
completion of opening stroke.
4 - After 3 sec of opening or close travel, the electronic torque increase gets in operation.
Set the electronic torque through the trimmer TORQUE.
5 - On completion of checks and setting of trimmer, set the DIP1 on OFF. The LED DL1 turns
off (in case still lit) to indicate the end of control phase.
N.B.: While performing this check, photcells and safety strips are overridden.
D - MANNED POSITION OPERATION
In such mode the remote control will not operate.
Set DIP1 on ON the LED DL1 starts flashing. Flashing will end within 1 minute, unless any
operation is initiated.
To operate the fence depress and maintain the pushbutton "K Button".
In case the pushbutton is released the fence stops. Further depressing the pushbutton will
command motion of the fence in the opposite direction.
While working safety features (photocells and safety strip) are overriden.
E - TIME SETTING
Setting must be performed with the fence fully closed, with STROKE END SWITCHES
SET.
1 - Put DIP 2 in the ON mode => the LED DL1 emits short blinkings.
2 - Depress the pushbutton PROG => the fence opens
3 - After 2 seconds from the fence reaches the full open position, depress the
pushbutton PROG to set the operation time of the fence.
17
G
B

Publicité

Table des Matières
loading

Table des Matières