WAGNER WALL EXTRA I-SPRAY 1800 Mode D'emploi page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
CAUTION! Never clean seals, diaphragm and nozzle or air
holes of the spray gun with metal objects.
The ventilation hose and diaphragm are only solvent-resistant to a limited
extent. Do not immerse in solvent, only wipe.
9. Pull the ventilating hose (fig. 1 A, 15) at the top from the gun body. Screw off the valve
cover (16). Remove the diaphragm (17). Clean all the parts carefully.
10. Remove the adjustment ring (fig. 6, 1) carefully from the union nut (2).
11. Unscrew the union nut (fig. 6, 2) and remove the air cap (3), air screen (4), and nozzle (5).
Clean the air cap, air screen, nozzle seal (6) and nozzle with a brush and solvent or water.
Assembly
The I-Spray nozzle, air cap and needle are optimally adjusted to suit each
i
other. Do not combine components with different spray attachments, as the
components could be damaged.
CAUTION! The units may only be used with a functional valve. If paints
rises in the ventilating hose (Fig. 1 A, item 15) do not operate the unit
further! Dismantle and clean the ventilating hose, valve and diaphragm
and replace the diaphragm if necessary.
1. Place the diaphragm (fig. 1 A, 17) with the pin facing upwards on the bottom section
of the valve. Also see the marking on the gun body.
2. Place on the valve cover (fig. 1 A, 16) and screw it closed.
3. Place the ventilating hose (fig. 1 A, 15) on the valve cover and on the nipple at the gun
body.
4. Push the nozzle seal (Fig. 7, 6) over the needle (7); the groove (slot) should point towards
you.
5. Place the nozzle (Fig. 7, 5) on to the gun body with the recess facing downwards.
Attention: Position of needle must be congruent with the nozzle aperture.
(Fig. 8)
6. Put the air screen (fig. 9, 4) in the air cap (3). Put both on the nozzle (5) and secure with
the union nut (2).
7. Adjust the setting ring (fig. 10, 1) so that the two "horns" grip the air cap and the red
adjustment lever rests on the pin.
8. Place the container seal from below on the suction tube and slide it over the collar,
while turning the container seal slightly.
9. Insert the suction tube with container seal in the gun body.
10
Wall Extra I-Spray 1800

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2361749

Table des Matières