9 Cleaning the Unit
GB
The optical parts (lenses and mirrors) should be
cleaned at regular intervals, depending on impuri-
ties caused by dust, smoke or other particles. Only
this will ensure that the light is radiated at maximum
brightness. For cleaning, disconnect the mains
plug from the socket. Only use a soft, clean cloth
and a detergent for glass.
For cleaning the other parts of the housing, only
use a soft, clean cloth. Never use any fluid; it may
leak into the unit and cause damage.
10 Specifications
Power supply: . . . . . . . 230 V~ / 50 Hz
Power consumption: . . 30 VA
Illuminant: . . . . . . . . . . 78 super bright LEDs
Ambient temperature: . 0 – 40 °C
Dimensions: . . . . . . . . 37 × 19 × 32 cm
Weight: . . . . . . . . . . . . 4 kg
Subject to technical modifications.
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
14
(30 × red, 24 × green,
24 × blue)
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
®