A_AD
16.05.2007
8:22 Uhr
63
Supply voltage:
Motor protection:
Degree of protection:
Winding class:
Temperature class:
Ambient temperature:
Media temperature:
Max. system pressure:
Required operating:
Noise:
Leakage current:
Seite 63
english
10. Specifications
1×230-240 V +6/-10%, 50 Hz
No external motor protection is necessary
IP 42
insulation class F
TF 95
max. 40 °C
+15 °C bis 95 °C, for short periods (ca. 30 min) 110 °C
The temperature of the medium must be higher
than the ambient temperature to prevent condensation water
from forming in the terminal box and the stator.
Ambient temperature
°C
15
20
25
30
35
40
1)
for short periods, ca. 30 min
16 bar
at 75 °C water temperature and 500 m above sea level
A 402, A 402-1
A 501, AD 501
A 502, AD 502
A 651, AD 651
A 652, AD 652
Addition for higher temperatures
95 °C
110 °C
Each ±100 m altitude
sound pressure level under 55 dB(A)
The pump's power line filter causes a leakage current
to the ground wire of less than 3.5 mA during operation.
11. Disposal
This product and the special electronic components (lead-free)
must be disposed of in accordance with the environmental
regulations.
Media temperature
Min. °C
15
20
25
30
35
40
0,4
bar
0,2 bar
0,5 bar
0,35 bar
1,0 bar
+ 0,45 bar
+ 1,10 bar
± 0,01 bar
Max. °C
95 / 110
1)
95 / 110
95 / 110
95 / 110
90 / 90
1)
70 / 70