Supply Terminals - ITT A 402 Serie Instructions D'installation Et D'entretien

Circulateurs de chauffage
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A_AD
16.05.2007
8:22 Uhr
54
Seite 54
english
Rated current Output control system
min.
Power
Output control system
min.
Rated current Output control system
min.
Power
Output control system
min.
Rated current Output control system
min.
Power
Output control system
min.
5.1 Supply terminal
If the connection or the voltage is incorrect,
the motor may be damaged!
Mains connection 1×230 V
PE wire, protective conductor
L
Lead
N Neutral line
1× 230-240V +10/–10%, 50Hz
When using fault current safety switches (FI), a model that is
sensitive to pulses has to be used; it must take the charging
current and earthing into account when the power is switched
on and be suitable for the pump's leakage current.
The FI switches have to be marked
with the symbol shown.
Comment:
The supply voltage has to be switched off before any work is done
in the pump's terminal boxes.
Be careful when opening the lid for the electronics!
The electronics may have current for up to 10 minutes
after the power has been switched off.
A 402
A 501
A 402-1
AD 501
0,25 ... 2 A
0,25 ... 1,3 A
0,5 A
0,45 A
25 ... 420 W
35 ... 275 W
50 W
85 W
A 502
AD 502
0,45 ... 3,4 A
0,5 A
70 ... 720 W
70 W
A 651
A 652
AD 651
AD 652
0,45 ... 3,4 A
0,48 ... 4,3 A
0,5 A
0,55 A
70 ... 720 W
70 ... 930 W
70 W
70 W

Publicité

Table des Matières
loading

Table des Matières