Drum lifter with hydraulics:
Regularly check the hydraulic system oil level and for leaks. If necessary tighten the screws or change the
seals if oil is leaking. If filling with oil is needed ensure hydraulic oil meeting ISO VG 46 is used. Only
qualified personnel should do this.
The load chain should be checked along its entire length, even where parts are hidden.
If the following damage is detected on the chain, the drum lifter must no longer be used:
a) Any lengthening of the chain or individual links
b) Breakage of a link
c) Cracks in a link
d) Deformation of a link
e) Wear where the bolts are fitted
Drum lifter with cable winch
Always ensure the winch is in good operating condition. Machinery which is not maintained can lead to
incorrect operation and accidents.
The lifting cable should be checked along its entire length, even where parts are hidden.
If the cable is damaged, the drum lifter should be withdrawn from service and the cable replaced.
Replacement parts
Description
Strap with ratchet
Strap with ratchet, antistatic
for Ex version
9. Types FH-EX (Ex version equipment)
9.1 Application and intended use
in addition to section 3. For the "Application and intended use" of Ex version equipment, the following notes
apply:
The product must only be used in accordance with the instructions and the product identification. The
identification is located on the product identification plate.
9.2 Additional Instructions
In addition to the previous section, for Ex version equipment the following notes apply:
The drum lifter must only be unpacked in a non-Ex area.
Handling flammable liquids, explosion protection measures
During the handling, storage and dispensing of substances which can create an explosive atmosphere,
the requirements of ATEX Directive 94/9/EC and 1999/92/EC must be observed in addition to the 11th
Machinery Safety Law (GSGV) and the Industrial Safety Regulations (BetrSichV). Depending on the Ex-
zone, suitable protective measures are to be taken. Emphasis must be laid on preventing a build-up of
explosive atmosphere by altering the concentration (eg ensuring sufficient ventilation), operating
conditions, and constructive organisation (eg using suitable and approved containers, suitable storage
facilities).
It must be ensured that sources of ignition caused by electrostatic charges are avoided by using electrical
equipotential bonding. Mechanically produced sparks must be avoided by using suitable tooling, transport
184360_BA_INT_008 Fasslifter Servo mit Prismengreifer
181088, 181090, 115293, 115295
181089, 181091, 147723, 147722
Item No.
100192
232324
Seite 13 von 33 Seiten
Ausgabe 09/2015