Intended Use Of The Equipment - Denios DT 1 / 60 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Claims for defects and liability
DENIOS is not liable for claims for defects, damage or injury to persons or property caused by one or more of the
following:
Misuse
Incorrect assembly, commissioning, operation or maintenance
Non-observance of the notices in these operating instructions
Use of the product when defects or faults are present
Incorrectly conducted repair work
Vandalism
Catastrophe situations caused by the effect of foreign bodies and force majeure
Independent conversion of the product
Observe the following safety instructions for use in Ex zones:
During the handling, storage and dispensing of substances which can create an explosive atmosphere, the
requirements of ATEX Directive 1999/92/EC must be observed. Depending on each Ex zone, you must take
measures to prevent the ignition of an explosive atmosphere in each individual case.
Use suitable techniques to avoid sources of thermal ignition, for example friction, lightning, open flames,
open lights and smoking.
Avoid mechanically produced sparks by using suitable tooling, suitable transport and loading equipment.
Avoid exceeding the permitted electrical conductivity values which are set out in the standards. These
values can change depending on the depositing of hindering substances and also by chemical and
mechanical influences. In particular, dust, dirt, paint, acids and alkalis can reduce or completely prevent the
conduction of electrical/electrostatic energy to the floor.
Before every use of the drum dolly in an Ex zone check the castors for dirt and foreign bodies and clean
them if necessary.
Check the drum dolly for any corrosion damage. If corrosion damage is present the drum dolly must not be
used.
When using the drum dolly in an Ex zone, all objects which can come into contact with the drum dolly must
be electrically conductive:
2.1

Intended use of the equipment

NOTICE
Only the dissipative versions of the drum dolly are suitable for use in Ex zones.
Observe the additional information regarding Ex zones, the safety instructions and the manufacturer's declaration
given in these operating instructions.
The drum dolly is used for the safe internal transport of drums of various sizes. This includes:
212 - 230 litre steel ribbed drums in accordance with DIN EN 15750-2
208 - 216 litre steel lidded drums in accordance with DIN EN 15750-1
60, 120 and 220 litre plastic lidded drums
110 and 220 litre plastic L ring drums
60 litre steel ribbed drums
09-18
o
Only use dissipative drums.
o
Check to ensure the drum is suitable.
Drum dolly 009_INT