Design and Function
Attention!
!
Hazards must be ruled out before a key can be entered and
the movable part of the guard can then be opened!
The solenoid locking unit is to be integrated into a system and connected
with a control unit so that the hazardous machine can run only when the
guard is locked and closed.
After entering a key into key module the actuator can be removed from
actuator module and the access can be opened.
The key is blocked after removing the actuator. Only after the access is
locked and the actuator was returned to its starting position can the first
key be removed again and the solenoid locking is activated.
Mechanical guard locks are used in the system in connection with addi-
tional STS units and SAFEMASTER products. The key to be entered may
originate from these units (e.g. release through upstream solenoid locking
ZRH01A in connection with a speed monitor UH 5947 or standstill monitor
LH 5946).
20
SAFEMASTER STS-M10A, M10BM, MK011M / 10.12.19 en / 137A