Design And Function; Indication; Circuit Diagrams - DOLD ZRHB01M Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Design and Function

Solenoid locking units prevent opening of separating guards and keep
them closed as long as their is a risk of injury in the secured plant.
Attention!
!
Hazards must be ruled out before a key can be removed and
the movable part of the guard can then be opened!
The solenoid locking unit is to be integrated into a system and connected
with a control unit so that the hazardous machine can run only when the
guard is locked and closed.
An access can only be opened after a release signal was sent by the
machine control to the ZRHB01M solenoid locking unit. The actuator
can only be removed from actuator module B and the access opened
after removing the key from key module 01. Key operation is not forced.
Key entry is not blocked when the door is open. The key can be entered
again after the access was closed again. Only after entering the key is the
solenoid locking activated again and the machine can be restarted.
Key and magnet position are monitored by separate contacts.
ZRHB01M is usually used in the system in connection with additional
STS units and SAFEMASTER products (e.g. release by speed monitor
UH 5947, standstill monitor LH 5946 or speed/standstill monitor BH 5932).
The key with forced removal can be used as protection against lock-in.

Indication

LED red:
LED yellow/green:
Magnet energized
Separately controllable

Circuit Diagrams

3
14
2
11
12
1
6
22
4
21
24
5
20
32
31
19
11
52
10
51
54
9
8
42
41
7
17
62
61
18
16
15
red
24
yellow
23
22
green
21
12
M11407_b
Fig. 1:
Solenoid locking activated:
Magnet locked,
Key inserted
3
14
2
11
12
1
6
22
4
21
24
5
20
32
31
19
11
52
10
51
54
9
8
42
41
7
17
62
61
18
16
15
red
24
yellow
23
22
green
21
12
M11413_b
Fig. 3:
Solenoid locking deactivated:
Magnet released,
actuator removed
20
3
14
2
11
12
1
6
22
4
21
24
5
20
32
31
19
11
52
10
51
54
9
8
42
41
7
17
62
61
18
16
15
red
24
yellow
23
22
green
21
12
M11410_b
Fig. 2:
Solenoid locking deactivated:
Magnet released,
Key inserted
ZRHB01M, ZRHB02M
Mechanical switch
positions
Circuit diagram
3
2
3
1
6
4
6
5
19
20
11
9
11
10
7
8
17
18
De-energized
on trip
15
16
Open circuit
operation
15
16
closed
open
The state shown in Figure 3 does
not depend on the control signal of
the magnet.
If the control signal is applied and
the actuator inserted the solenoid
locking changes to the state of
Figure 2.
If no signal is applied and the
actuator is inserted the solenoid
locking changes to the state of
Figure 1
SAFEMASTER STS-ZRHB01M / 05.12.19 en / 166A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Safemaster sts zrhaSafemaster sts zrhbmZrh01m

Table des Matières