Design and Operation

Attention!
Hazards must be ruled out before the movable part of the
!
guard can then be opened! and the dangerous location can
be reached!
Optionally, another key can be removed. The STS/K switch units are to
be integrated into a system and connected with a control unit so that the
hazardous machine can run only when the guard is locked and closed.
After entering a first key into key module 10/K (RX10B01M/K) the contacts
switch and the actuator can be removed from actuator module B/K and the
access can thus be opened. The first key is blocked and the second key
released after removing the actuator. The actuator is blocked when the
second key is removed from key module 01/K. This ensures an escape
route. Only after the second key and the actuator (access is locked) were
returned to their starting position can the first key be removed again and
the solenoid locking is activated.
With the RX10K01M/K, the first key is inserted into key module 1 and the
actuator can be removed. After removing the actuator, the 2nd key can
be removed. When the 2nd key is removed, the contact switch and the
actuator is blocked.
RX10B01M/K and RX10K01M/K are used in the system in connection
with additional STS/K units and SAFEMASTER products. The first key to
be entered may originate from these units (e.g. release through upstream
solenoid locking ZRH01BM/K in connection with a speed monitor UH 5947
or standstill monitor LH 5946). The second key, optionally to be removed,
can serve as protection against lock-in or for the operating release of
additional units (e.g. M10BM/K, M11BM/K, M12M/K, M10B01M/K). On the
base unit RX10B01M/K the key can be also be used as an authoritzation
key.

Indications

LED red/green
Separately controllable

Circuit Diagrams RX10B01M/K

3
14
2
11
12
1
9
22
11
21
24
10
7
32
8
31
4
red
5
green
6
12
M9895_b
Fig. 1:
Locked while activated:
1st key removed, Actuator inserted,
2nd key inserted, Door closed

Circuit Diagrams RX10K01M/K

3
14
2
11
12
1
9
22
11
21
24
10
7
32
8
31
4
red
5
green
6
12
M9895_b
Fig. 1:
Lock deactivated:
1st key inserted, Actuator removed,
2nd key removed, Door open
20
SAFEMASTER STS-RX10B01M/K and RX10K01M/K / 22.06.20 en / 246A
3
14
2
11
12
1
9
22
11
21
24
10
7
32
8
31
4
red
5
green
6
12
M10174
Fig. 2:
Lock deactivated:
1st key inserted, Actuator removed,
2nd key removed, Door open
RX10B01M/K
Mechanical Switch
Positions
Circuit Diagram
3
2
3
1
9
10
9
11
7
8
closed
open
3
14
2
11
12
1
9
22
11
21
24
10
7
32
8
31
4
red
5
green
6
12
M10174
Fig. 2:
Locked while activated:
1st key removed, Actuator inserted,
2nd key inserted, Door closed
RX10K01M/K
Mechanical Switch
Positions
Circuit Diagram
3
2
3
1
9
10
9
11
7
8
closed
open