Fault
The swivel arm cannot be
opened or closed because
the tool is jammed in the
bowl.
Information on display panel
Fault
"5000 g" or "11.00 lb" is
flashing on the display.
"-990 g" or "-2.20 lb" is flash-
ing on the display.
"59:59 m:s" is flashing on
the display.
The display shows "ERROR" Scales are exposed to ex-
Cause
Drive is not in the parked po-
sition after a safety system
has stopped processing or
the power supply has been
interrupted.
Cause
Display values of the scales
have been exceeded.
Display values of scales
have not been attained.
Display range of the timer
has been exceeded.
cessive vibrations.
Base is uneven.
The feet are soiled.
The scales have to be restar-
ted.
Troubleshooting en
troubleshooting
Set the rotary switch to
1.
Eliminate the problem that caused
2.
the appliance to stop.
→ "Safety systems", Page 41
When the swivel arm is open, re-
3.
move the tool and close the swivel
arm.
Set the rotary switch briefly to and
4.
then back to
a The drive remains on for a short
time until the parked position is
reached.
troubleshooting
Observe the display values of the
▶
scales.
→ "Display values of scales",
Page 45
Observe the display values of the
▶
scales.
→ "Display values of scales",
Page 45
Process food for not longer than
▶
59 minutes and 59 seconds or re-
set the processing time within this
time.
→ "Reading off and resetting the
processing time", Page 46
Do not use the appliance on work-
▶
tops exposed to vibrations, e.g. with
a dishwasher running underneath.
Set up the appliance on a stable,
1.
level, clean and flat work surface.
Check whether all 4 feet are in con-
2.
tact with the work surface.
▶
Wipe the feet down with a damp
cloth.
To restart the scales:
1.
Press .
‒
Wait 30-60 seconds.
‒
.
.
51