MAINTENANCE

Cleaning the Comfort Panel
• Open the Comfort Panel by turning the knobs.
• Unfasten the panel from the hood canopy by sliding the fixing
pin lever provided.
• The comfort panel must never be washed in the dishwasher.
• Clean the outside with a damp cloth and neutral detergent.
• Clean the inside using a damp cloth and neutral detergent; do
not use wet cloths or sponges, or jets of water; do not use abra-
sive substances.
• On completing the operation, hook the panel up to the hood
canopy again and close it by turning the knobs in the opposite
direction.
These can be washed in the dishwasher, and need to be cleaned whenever
the FF sign appears on the display or at least once every 2 months use, or
more frequently if use is particularly intensive.
Resetting the alarm signal
• Turn the Lights and the Suction motor off, then disable the 24h func-
tion, if enabled.
• Press button E until the display turns off.
Cleaning the Filters
• Open the Comfort Panel by turning the knobs.
• Remove the Filters one at a time, pushing them towards the back of the
unit and at the same time pulling downward.
• Wash the Filters without bending them, and leave them to dry com-
pletely before replacing. (If the surface of the filter changes colour as
time goes by, this will have absolutely no effect on the efficiency of
the filter itself.)
• Replace, taking care to ensure that the handle faces forwards.
• Close the Comfort Panel by turning the knobs.