Trouble Shooting; Fault Correction - Parkside PNTS 1500 B3 Traduction Des Instructions D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54
GB

Trouble shooting

Problem
Device does not start
Low or lack of
suction
Float does not switch
the appliance off
Dust or dirt is blow
out of the device
16
Possible cause
Mains voltage is not
present
Defective on/off switch
(
10)
Worn carbon brushes
Defective motor
Hose system (
18/19) or
jets (
21-24) blocked
Air control on the handle
(
15) open
Collector (
5) open
Collector (
5) full
Filter (
11/12/13) full
or clogged
Float cannot move
Float faulty
Float cannot move
Float faulty
Filter (
11/12/13) is not
or not correctly assembled

Fault correction

Check plug socket, cable, line,
plug and fuse, where appropriate,
repair through electrical specialist
Repair through customer service
Remove obstructions and blockages
Close the air control
Close collector
Empty collector
Empty, clean or replace filter
Release float
Repair by Customer Care
Release float
Repair by Customer Care
Use missing filters or check the cor-
rect position of the filter

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

104474

Table des Matières