OFAS HL provides 5 stages of contamination reduction for 8 contaminants (if liquid water or oil is present, the CDAS HL must be protected by an
optional OIL-X WS grade Water Separator)
Stages of Purification: 5
Contaminants Reduced: 8 (10 with optional Water Separator*)
Stage 1 - General Purpose
Coalescing Filter
For the reduction of water
and air aerosols down to
3
0.5mg/m
(0.5ppm(w) and
particulate down to 1
micron.
Provides protection of the
High Efficiency Coalescing
Filter and Dryer.
Stage 5 - General Purpose
Stage 4 - Oil Vapour
Dry Particulate Filter
For the reduction of
For the reduction of oil
particulate down to 1
micron
* Optional Water Separator only needed if liquid oil or water is
present at the inlet to purification system (Not a requirement
for all compressed air systems).

2.2 EST - Energy Saving Technology

Heatless adsorption dryers consume energy through the use of process air called purge air which is used to regenerate the off-line desiccant bed.
In order to provide a consistent outlet dewpoint, any compressed air dryer must be sized to reduce the highest amount of water vapour the dryer
will see (full flow demand in summer conditions). Adsorption dryers typically operate on fixed timing cycles based upon these worst case
conditions, however in periods of low demand and or in winter, when the moisture loading is reduced, the fixed cycle will consume more energy
than is required. In order to significantly reduce this energy loss, each CDAS HL/ OFAS HL dryer is fitted with energy saving technologies as
standard.
Each CDAS HL / OFAS HL includes an electronic control system with colour display, providing a visual indication of the unit's performance.
Linked to this control system is the a dewpoint sensor which constantly monitors the outlet dewpoint and adjusts the regenerating cycle to exactly
match the water vapour loading of the dryer. From the minute the system is operated, it is automatically adapting to ambient and duty conditions,
saving air, energy and money.
Side A
Side B
Drying
4
Stage 2 - High Efficiency
Coalescing Filter
For the reduction of water
and air aerosols down to
3
0.01mg/m
(0.01ppm(w)
and particulate down to
0.01 micron.
Provides protection for the
Dryer.
Stage 3 - Adsorption Dryer
Removal Filter
For the reduction of water
vapour.
vapour down to
Standard PDP of -40
3
o
0.003mg/m
Option for -70
C PDP or
o
-20
C PDP
Depressurisation
OFAS Operation
o
C
EMS Drying and Regeneration Cycle
Time (Seconds)
Regeneration
Repressurisation
Energy Saving (EMS)