HOOfDSTUk 3
WAArScHUWING
WAArScHUWING
3.5 Uitgangsaansluiting
WAArScHUWING
3.5.1 Uitgangskabels (door klant geleverd)
Kies plasmasnij-uitgangskabels (door de klant geleverd) op de basis van 4/0 AWG, 600 volt geïsoleerde koperka-
bel voor elke 400 A uitvoerstroom.
EEN ELEkTrIScHE ScHOk kAN DODELIjk ZIjN!
DE rINGTErMINALS MOETEN rUIMTE HEbbEN TUSSEN HET ZIjPA-
NEEL EN DE HOOfDTrANSfOrMATOr. DE rUIMTE MOET VOLDOEN-
DE ZIjN OM bOOGVOrMING TE VOOrkOMEN. ZOrG DAT DE kAbELS
NIET IN bOTSING kOMEN MET DE DrAAIENDE VENTILATOr.
ONjUISTE AArDING kAN DOOD Of LETSEL TOT GEVOLG HEbbEN.
HET cHASSIS MOET ZIjN AANGESLOTEN OP EEN GOEDGEkEUrDE
ELEkTrIScHE AArDE. cONTrOLEEr Of DE AArDE NIET IS AANGESLO-
TEN OP EEN PrIMAIrE TErMINAL.
EEN ELEkTrIScHE ScHOk kAN DODELIjk ZIjN! GEVAArLIjk VOLTA-
GE EN STrOOM!
WANNEEr U WErkT rOND EEN PLASMAVOEDINGSbrON MET VEr-
WIjDErDE PANELEN:
•
HAAL DE STEkkEr UIT HET STOPcONTAcT.
•
LAAT EEN ErkEND PErSOON DE UITGANGSbUSbALkEN (POSITIEf
EN NEGATIEf) MET EEN VOLTMETEr cONTrOLErEN.
Opmerking:
Gebruik geen geïsoleerde laskabel van 100 volt.
72
INSTALLATIE