3.5 output connections
WarnIng

3.5.1 output cables (customer supplied)

Choose plasma cutting output cables (customer supplied) on the basis of one 4/0 AWG, 600 volt insulated cop-
per cable for each 400 amps of output current.
electrIc shock can kIll!
rIng terMInals Must have clearance BetWeen sIDe panel
anD MaIn transforMer. clearance Must Be suffIcIent to
prevent possIBle arcIng. Make sure caBles Do not Inter-
fere WIth coolIng fan rotatIon.
IMproper grounDIng can result In Death or InjurY.
chassIs Must Be connecteD to an approveD electrIcal
grounD. Be sure grounD leaD Is not connecteD to anY prI-
MarY terMInal.
electrIc shock can kIll! Dangerous voltage anD current!
anY tIMe WorkIng arounD a plasMa poWer source WIth cov-
ers reMoveD:
DIsconnect poWer source at the lIne (Wall) DIsconnect.
have a QualIfIeD person check the output Bus Bars (posI-
tIve anD negatIve) WIth a voltMeter.
Do not use 100 volt insulated welding cable.