Direction Of Rotation; Lubrication; Oil Capacity - Speedaire 35WC82 Instructions D'utilisation Et Manuel De Pièces

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS
(CONTINUED)

Direction of Rotation

NOTE: Improper rotation will result in reduced compressor
life.
The direction of rotation must be counterclockwise (as
shown by the arrow on the flywheel in Figure 7) while facing
the flywheel side of the pump. The motor nameplate will
show wiring information for counterclockwise rotation.
The proper direction is very important. The direction of
rotation of 3 phase motors can be reversed by interchanging
any two motor-line leads. For single phase motors, refer to
the motor nameplate.

Lubrication

This unit contains no oil.
Before operating compressor, fill
to the center of the sight gauge (see Figure 8).
Using any other type of oil may
shorten pump life and damage
valves.
Recommended Oil (2 Options)
Single viscosity SAE 30 ISO100 nondetergent
compressor oil. Grainger part number 1WG49.
10W30 synthetic oil such as Mobil 1

Oil Capacity

Approximately 0.5 quarts
Fill the pump with oil to the center of the sight gauge
using oil fill opening (see Figure 8).
pump through the breather cap opening as this may
cause oil to leak and spray out during operation.
NOTE: Some residual oil may still be in the pump from
factory testing leaving a thin coat on the sight gauge;
however, there is not enough oil to operate the unit.
Figure 7- Direction of rotation
®
.
Do NOT fill the
Figure 8
Full
Low
Sight Gauge
Oil Drain Plug
Oil Fill
Breather Cap
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

35wc83

Table des Matières