GREEN
GROUND
SCREW
NEUTRAL
GROUND
WIRE
STRAIN
RELIEF
MOUNTING
BRACKET
7. Tighten the screws securing the cord restraint firmly against the power
cord.
8. Tighten the strain relief nut securely so that the strain relief does not
turn.
9. Reinstall the terminal block cover.
ELECTRICAL CONNECTIONS
FOR 4-WIRE SYSTEM
NON-CANADIAN ELECTRIC Dryer
1. Remove the screws securing the terminal block access cover and
the strain relief mounting bracket located on the back of the dryer
upper corner.
2. Install a U.L. approved strain relief in the entry hole of the mounting
bracket. Finger tighten the nut only at this time.
3. Remove the ground wire from the green ground screw located
above the terminal block.
GREEN
GROUND
SCREW
NEUTRAL
GROUND
WIRE
RED
4. Thread a U.L. approved 30 amp power cord, NEMA 14-30 type ST or
SRDT through the strain relief.
TYPICAL 4
CONDUCTOR
30 AMP NEMA 14-30 TYPE SRDT OR ST
5. Attach the green power cord ground wire to the cabinet with the
green ground screw.
6. Attach the white (neutral) power cord conductor from the power cord
and the neutral ground wire from the dryer harness to the silver-
colored center terminal on the terminal block. Tighten the screw
securely.
7. Attach the red and black power cord conductors to the outer brass-
colored terminals on the terminal block.
Do not make a sharp bend or crimp wiring/
conductor at the connections.
8. Tighten the screws securing the cord restraint firmly against the power
cord.
9. Tighten the strain relief nut securely so the strain relief does not turn.
10. Reinstall the terminal block access cove
SILVER
TERMINAL
NUT
TIGHTEN NUT
TO THESE
THREADS
POWER CORD
GREEN POWER CORD
GROUND WIRE
SILVER TERMINAL
TERMINAL
BLOCK
TIGHTEN
BLACK
NUT
WHITE
TO THESE
THREADS
NUT
STRAIN
RELIEF
MOUNTING
BRACKET
POWER
CORD
BLACK
TYPICAL 4
CONDUCTOR
WHITE
RED
GREEN
r.
GAS CONNECTION
1. Remove the shipping cap from gas pipe at the rear of
the dryer.
NOTE: DO NOT connect the dryer to L.P. gas service without
converting the gas valve. An L.P. conversion kit must be installed by a
qualified gas technician.
2. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from
gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of
the dryer (see pages 6 and 7). Use a 1/2 inch to 3/8 inch (1.27 cm to
0.96 cm) reducer for a connection. Apply an approved thread
sealer that is resistant to the corrosive action of liquefied gases on
all pipe connections.
3. Open the shutoff valve in the gas supply line to allow gas to flow
through pipe.
4. Test all connections by brushing on a soapy water solution. NEVER
test for gas leaks with an open flame.
GENERAL INSTALLATION
1. Connect the exhaust duct to outside exhaust system (see pages 3
and 4). Use duct tape to seal all joints.
2. With the dryer in its final position, adjust one or more of the legs
until the dryer is resting solid on all four legs. Place a level on top of
the dryer. The dryer MUST be level and resting solid on all four
legs.
3. Plug the power cord into a grounded outlet. NOTE: Check to
ensure the power is off at circuit breaker/fuse box before plugging
the power cord into the outlet.
4. Turn on the power at the circuit breaker/fuse box.
Before operating the dryer, make sure the dryer area
is clear and free from combustible materials, gasoline, and other
flammable vapors. Also see that nothing (such as boxes,
clothing, etc.) obstructs the flow of combustion and ventilation
air.
5. Run the dryer through a cycle check for proper operation.
NOTE: On gas dryers, before the burner will light, it is
necessary for the gas line to be bled of air. If the
burner does not light within 45 seconds the first
time the dryer is turned on, the safety switch will
shut the burner off. If this happens, turn the timer
to "OFF" and wait 5 minutes before making another
attempt to light.
6. If your dryer does not operate, please review the "Avoid Service
Checklist" located in your Use and Care Guide before calling for
service.
7. Place these instructions in a location near the dryer for future
reference.
NOTE:
A wiring diagram is located inside the dryer console or under
the top panel.
REPLACEMENT PARTS
Pedestal
A pedestal accessory, Model No. NLPWD15, specifically designed for this
dryer may be used when elevating the dryer for ease of use. Failure to use
accessories certified by the manufacturer could result in personal injury,
property damage or damage to the dryer.
If replacements parts are needed for your dryer, contact the source
where you purchased your dryer.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Destroy the carton and plastic bags after the dryer is
unpacked. Children might use them for play. Cartons covered with
rugs, bedspreads, or plastic sheets can become airtight chambers
causing suffocation. Place all materials in a garbage container or make
materials inaccessible to children.
The instructions in this manual and all other literature
included with this dryer are not meant to cover every possible condition
and situation that may occur. Good safe practice and caution MUST be
applied when installing, operating and maintaining any appliance.
8
VALVE OPEN / GAS FLOW POSITION