STUDIO SCAN XTD825 / 625™
10-4. COMMANDS AND RESPONSES TABLE
The following table resumes commands which are recognized as valid and the responses that will be returned to the control
device (on RS-232 port).
ASCII
RESPONSE
COMMAND
FRONT PANEL COMMANDS
z
FRZ
a
ASP
h
HP
v
VP
w
HW
s
VS
H
ZHP
V
ZVP
W
ZHW
S
ZVS
R
REC
M
STO
INPUT COMMANDS
*
D
RGBI
GP
REFH
GS
REFS
GL
GLD
E
SOGI
l
LOAD
OUTPUT COMMANDS
F
OFMT
GR
REFR
e
OSIG
P
OPAT
IMAGE COMMANDS
f
FLK
k
BLK
r
RLV
g
GLV
b
BLV
L
HSMT
yp
PRES
CONTROLS COMMANDS
yl
LOCK
yc
EPOS
Y
FRES
xu
VERU
xi
I_
NOTE: * = available with the optional DVI input only.
COMMAND
DESCRIPTION
FREEZE.
Size mode selection.
Horizontal position adjustment.
Vertical position adjustment.
Horizontal size adjustment.
Vertical size adjustment.
Zoom horizontal position.
Zoom vertical position.
Zoom horizontal size.
Zoom vertical size.
RECALL.
STORE.
Input type
Genlock H phase adjustment
Genlock subcarrier phase adjustment.
Genlock load.
SOG input selection.
H sync load selection.
Output standard selection
Synchronization mode selection.
RGB/YUV output selection.
Test pattern selection.
Flicker level selection.
Black level adjustment
Red level adjustment.
Green level adjustment.
Bleu level adjustment.
Horizontal smooth
PRESET
Front panel locking selection.
Erase memory.
Default value.
Device version
Identification number.
Chapter 10 : RS-232 PROGRAMMER'S GUIDE (continued)
TYPE
MIN MAX
Rd/Wr
0
1
0 = freeze inactive
Rd/Wr
0
2
0 = underscan.
2 = ZOOM.
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255 0 = 100%
Rd/Wr
0
255 0 = 100%
Rd/Wr
0
1
1 = recall (automatic reset)
Rd/Wr
0
1
1 = store (automatic reset)
Rd/Wr
0
1
0 = analog
Rd/Wr
0
255
Rd/Wr
0
65535
Rd/Wr
0
1
0 = Hi-Z
Rd/Wr
0
1
0 = no
Rd/Wr
0
1
0 = Hi-Z
Rd/Wr
0
7
0 = NTSC
1 = PAL
2 = NTSCj.
Rd/Wr
0
1
0 = internal.
1 = genlock.
Rd/Wr
0
2
0 = YUV.
1 = RGBS.
2 = RGsB.
Rd/Wr
0
1
0 = no test pattern.
1 = test pattern selected.
Rd/Wr
0
7
Rd/Wr
0
255
Rd/Wr
0
127
Rd/Wr
0
127
Rd/Wr
0
127
Rd/Wr
0
1
0 = OFF
Rd/Wr
0
1
1 = PRESET (automatic reset).
Rd/Wr
0
1
0 = unlocks all buttons. 1 = locks all buttons.
Rd/Wr
0
1
1 = erase all memories (automatic reset).
Rd/Wr
0
1
1 = set all the parameters to the default value
(automatic reset).
Rd
0
65535 Example: 104 = Version 1.4
Rd
0
65535 Value displayed in hexadecimal in the device.
Rd = Read only command.
Rd/Wr = Read and write command.
VALUE
DESCRIPTION
1 = freeze active.
1 = overscan.
255 =200%
255 =200%
1 = DVI
1 = 75 ohms.
1 = yes.
1 = 75 ohms.
1 = ON.
PAGE 21