Before assembly and initial operation of the device, check that the
delivery is complete and undamaged.
!
The device must only be repaired by authorized and skilled specialists.
Failure to observe this instruction risks damage resulting from improper
use and loss of the warranty.
!
Use the indoor unit at an operating temperature of + 5° C - + 40° C.
Higher or lower temperatures can adversely affect operation.
!
If required, a standard 12 V DC door release can be connected to the
system. The door release must be operated with 12 V DC and have a
max. current consumption of 1 A.
!
The mains cable for this door intercom must only be replaced by the
manufacturer or by an authorized specialist.
!
Install the outdoor unit so that it is protected from external influences
(e.g. rain or snow).
!
Make sure that the device is not exposed to strong static, electric or high
frequency fields (static discharge, mobile radiotelephone, radio sets,
microwaves). These may have an adverse effect on the function of the
door intercom.

Initial operation

Function
Handset
The receiver on the indoor unit is for speaking into and listening during
communication with the outdoor unit. The door release button [3] is used to
switch on a standard 12 V DC door release (not included). The latter can be
connected with a twin-core cable (with coded cores, not included).
Outdoor unit
The bell button [16] activates the bell on the indoor unit. The microphone
[18] is for speaking and the loudspeaker [15] for listening during
communication with the indoor unit.
The connection between the outdoor unit and the indoor unit can be made
with the twin-core cable (with coded cores). The length of the cable can be up
to approx. 200 m (see Technical data).
Choosing the installation positions
Danger!
when making the installation position, disconnect the indoor
unit from the mains power supply.
!
Decide on a suitable position for installation of the indoor unit, the
outdoor unit and optionally for the door release (see manufacturer's
instructions in the operating manual for the door release). Please make
sure that there is a mains socket for the mains power supply at a max.
distance of 1,5 m from the indoor unit.
!
You may install the indoor unit either on an even surface (shelf or
cabinet) or on a wall. Make sure that the cable is a suitable length.

Connection

!
Lead the twin-core cable from the installation site of the indoor unit to
the installation site of the outdoor unit.
!
Install the cable so that it is protected from external influences, e.g.
concealed, if necessary use a standard cable duct.
!
Make sure that you have approx. 0 cm of cable available for connection
directly at the connecting areas for the indoor unit and outdoor unit.
!
Carefully remove the insulation from the end of the cable cores to a
length of approx. 8 mm. The bared cores can be connected to the
terminal Screws.
Indoor unit (see Fig. B)
Caution!
make sure that the cable is connected correctly. The cable
must be connected according to the core coding. If the cores are connected
incorrectly, the door intercom cannot work properly.
!
Remove the mounting plate [10] from the indoor unit.
!
Guide the first cable (and a second if connecting a door release) through
the centre of the mounting plate and the cable opening [12].
!
Connect the first core (e.g. black) of the first cable (from the indoor unit
to the outdoor unit) to terminal screw 1 [6].
!
Connect the second core (e.g. white) of the first cable (from the indoor
unit to the outdoor unit) to terminal screw 2 [7].
Receiver
!
Push the plug of the receiver cable [4] completely into the receiver cable
socket on the handset (at the bottom in the centre of the handset ).
Optional for connection of a 12 V DC door release:
!
Carry out the installation and connection preparations for the door
release according to the manufacturer's instructions (operating
manual).
!
Connect the first core (e.g. black) of the second cable (from the door
release to the indoor unit to terminal screw S1 [8] and the
corresponding terminal screw of the door release.
!
Connect the second core (e.g. white) of the second cable (from the door
release to the indoor unit) to terminal screw S2 [9] and the
corresponding terminal screw of the door release.
Outdoor unit
!
Remove the retaining screw 1 [23] and take the housing [14] off the
flush mount box [19].
!
Guide the first cable through the cable opening [21].
!
Connect the first core (e.g. black) of the first cable (from the indoor unit
to the outdoor unit) to terminal screw 1 [24].
!
Connect the second core (e.g. white) of the first cable (from the indoor
unit to the outdoor unit) to terminal screw 2 [25].
!
With modell DP 602 connect the second core (eg. white) from the
second indoor unit to terminal screw 3 [26].
Figure E/F shows connection of all components (optionally with door
release).