1x <1s
Save Automatic Closing Timer /
P
call up reset function
Attention!
After a reset all parameters revert to the factory settings.
To ensure correct operation of the control:
- all functions desired must be re-programmed,
- the remote control unit must be re-programmed,
- the operator system must be driven once to the OPEN and
CLOSED position.
Select reset function
Confirm reset
Confirm "No reset"
1. Carry out reset / operator system
1x <1s
P
0. Carry out "No reset" /
Display number of door cycles:
- The display alternates the various digits
- the highest digit is shown flashing
For example 712 door cycles
1x <1s
End programming of the extended
P
functions
9.
Operation
Open the door / close the door
The garage door operator can be operated using the hand transmitter,
the (+) and (-) buttons on the door operator or an external input unit
(special accessory).
The door operator has a two-button direction function
1st Press (+):
door OPENS
2nd Press (+):
door stops
3rd Press (+):
door OPENS
4th Press (-):
door stops
5th Press (-):
door CLOSES
6th Press (-):
door stops
7th Press (-):
door CLOSES
The hand transmitter and the external input unit have an impulse
function:
1st impulse (button pressed): door OPENS
2nd impulse (button pressed): door stops
3rd impulse (button pressed): door CLOSES
4th impulse (button pressed): door stops
5th impulse (button pressed): door OPENS
...
Advice:
The drive system automatically carries out runs at regular intervals
as far as the mechanical stop in the OPEN direction to check
internal parameters.
Release mechanism
Release the door (fig. 9.1)
Lock the door (fig. 9.2)
12
changes to operating mode
call up door cycle counter
in the number
10. Malfunctions
Power interruption
Following a power interruption, at the first impulse the drive system
moves the door as far as it will go into the door OPENED position in
order to find its reference.
Fault messages
In the event of a fault message, the control displays the fault number
which flashes rapidly.
Indicator
Cause
If no buttons are pressed within 120 seconds, the
programming mode terminates automatically.
- RPM detector faulty /
anti-blocking device was
activated.
- Door movement too stiff.
- Door blocked.
- Maximum force is active
(linear curve).
- Excess travel stop.
- Undervoltage.
- Self test of the external
photocell barrier not OK.
- Faulty force sensor for the
automatic cut-out.
- Door movement too stiff
or irregular.
- Motor is not turning.
- Sensitivity (learned force
limitation) was activated.
- Electronics are defective.
- Stop circuit interrupted.
Legend:
LED segment off
LED segment flashes
ED segment flashes rapidly
LED segment lights up
Solution
- Check drive unit and
guide rails.
- Ensure that the door
moves easily.
- Have maximum force
checked by a specialist
dealer.
- Check drive unit and
guide rails.
- Check the building's
electricity supply.
- Have photocell barrier
checked.
- Check drive unit and
guide rails.
- Check the path of the
door.
- Ensure that the door
moves easily.
- Adjust OPEN or CLOSE
automatic switch-off
to less sensitive.
(level 1
-> level 16
sensitive
-> insensitive)
- Have sensitivity (learning
force curve) checked by a
specialist dealer.
- Check drive unit.
- Connect the stop circuit
or reset the door
operator.