Knob "LUX" (brightness setting)
This knob allows the switching threshold to be set, i.e. the ambient brightness at which
the motion switch is activated.
Turning the knob anticlockwise to the left, means the motion detector activates when
it is darker; turning it to the right, in direction of the sun symbol, the motion detector
activates in brighter ambiance.
Functional test
For a function test, a short operating period is to be set (turn knob "TIME" to the setting
of "10S"). Additionally, the knob for brightness ("LUX") must be turned all the way to
the right (to the sun symbol).
The desired sensitivity is to be set with the knob "SENS". For the first test, set the knob
in the middle position.
Now cross the detection range. The motion detector activates the connected device
when it recognises a movement in the detection range.
Adjust the knobs accordingly after the function test. See above.
Troubleshooting
The connected device is not switched on
• Check the settings of the knob "LUX" for the brightness control. When it is turned
too much anticlockwise to the left, the motion detector will be activated already in
darkness.
• Increase the sensitivity (turn the knob "SENS" in the "+" direction).
• Check whether there is a power supply, and whether the device, (i.e. a bulb) func-
tions.
• Rapid movements within the detection area are filtered out by the electronic system,
in order to prevent switching errors.
The connected device is switched on permanently
• If constant movements in the monitored area are detected, it can also be a move-
ment in a room nearby due to the HF technology in use. Increase the sensitivity (turn
the knob "SENS" in the "+" direction).
Please note: If the motion detector is activated due to a movement and a new move-
ment is recognised during the operating period, the operating period is reset!
• Set a very short switch-on time for testing, in order to narrow down the causes.
Maintenance and cleaning
The product is maintenance-free. Repair or maintenance work must be carried out
by a specialist.
You can use a clean, dry, soft cloth for cleaning. Dust can be very easily removed with
a soft, clean brush and a vacuum cleaner.
Do not use aggressive chemical or scouring cleaning agents, as this may lead to dis-
colouration or changes in the material on the surface.
Disposal
The product must not be disposed of with the household waste.
Dispose of the product at the end of its serviceable life in accordance with
the current statutory requirements; e.g., return it to any suitable collection
point.
Declaration of conformity (DOC)
We, Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare
that this product conforms to the fundamental requirements and other relevant regula-
tions of the 1999/5/EC directive.
The declaration of conformity (DOC) for this product can be found at:
www.conrad.com
Technical data
Operating voltage............................... 220 - 240 V/AC, 50 Hz
Internal power consumption ............ approx. 0.9 W
HF system ............................................ 5.8 GHz, CW radar, ISM band
Transmission power .......................... <0.2 mW
Switching capacity ............................ max. 1200 W (resistive load)
...............................................................
Devices with mainly resistive load are e.g., light bulbs, heaters, etc.
Devices with inductive load are, e.g., engines, control gears (e.g., for LEDs),
conventional transformers, energy saving bulbs, etc.
Switch type ......................................... relay, single-pole
Detection angle .................................. horizontal 360°, vertical 180° (see illustration in
Range ................................................... adjustable, for installation on wall approx. 5 - 15 m,
Recommended installation height ... for installation on ceiling 2 - 10 m, for installation
Speed
for recognition of movement ........... 0.6 - 1.5 m/s
Duty cycle............................................ adjustable 10 s (±3 s) to 12 min (±1 min)
Ambient brightness............................ adjustable, 3 to 2000 lux
Protection type ................................... IP44
Mounting location .............................. indoors/outdoors
Ambient conditions ............................ temperature -20 °C to +40 °C, relative humidity 0%
Dimensions.......................................... 85 x 104 x 80 mm (L x W x H)
Weight .................................................. 159 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE.
max. 300 W (inductive load)
chapter "Functional description")
for installation on ceiling approx. 2 - 8 m
on wall 2.5 - 3.5 m
to 93%